beautypg.com

CEMB USA C212 (A) User Manual

Page 9

background image

I 0648

- 9

1

2

1

2

1

2

1

2

1

2

GB

Fianco

interno

Fianco

esterno

To cancel this function, press

button again.

5.2.4 - OPPOSITE POSITION

In th

e normal balancing condition the weight is applied at 12 o'clock and shown

on the display.

The balancing machine can also indicate the correction position on the bottom


vertical line (see SETUP to select the O.P. function).This is very useful for cor

rection of light alloy rims with adhesive weights where the rim is normally clea

ned; the counterweight is pressed onto the rim surface in a visible area

5.2.5 - SPLIT FUNCTION (HIDDE

N ADHESIVE WEIGHTS)

The SPLIT function is used to position the adhesive weights behind the wheel spokes so that they are not visible.
This function should be used in ALU mode where the adhesive weight is applied on the outside. Input the wheel
dimensions and do a spin.

Turn the wheel to the outside unbalance correction position


as indicated by the machine

Position one spoke at 12 o'clock (e.g. 1) and press

Following the rotation direction indicated on the display, posi-

tion spoke 2 at 12 o'clock and press

Position the wheel as indicated by the LEDs.

The unbalance is indicated on the right-hand display

Repeat the operation for the other spoke

When the OPPOSITE POSITION function is enabled (see


relative paragraph) the correction position at 6 o'clock is also

indicated, so that the operator can easily insert the correction

weight by pressing it downward.

To return to normal unbalance display, press any button.

NOTE: The distance between the spokes must be at least 18° and at most 120° (if not, the errors 24 or

25 appear).Spokes with irregular or inconstant angles can be compensated.