beautypg.com

CEMB USA C212 (A) User Manual

Page 6

background image

I 0648

- 6

GB

4 - CONTROLS AND COMPONENTS

4.1 - CONTROL PANEL AND DISPLAY

1-2

Digital readouts, AMOUNT OF UNBALANCE, inside/outside

3-4

Digital readouts, POSITION OF UNBALANCE, inside/outside

5

Indicators, correction mode selected

6

Indicators, selection made

7

Push button, unbalance reading < 5 g (25 oz)

8

Push button, car/truck selection

9

Push button, selection STATIC unbalance

10

Push button, SPLIT (unbalance spread)

11

Push button, FUNCTIONS MENU

12

Push button, menu selection confi rmation

13

Push button, cycle start

14

Push button, emergency/home

15

Push button, position repeater

16

Manual dimension setting butto

ns

17

Push button to select grams/ounces as unit of measure for the unbalance

18

Digital display of the static unbalance value

19

Distance gauge position indication

20

Push button to select possible corrections

O

NLY

USE

THE

FINGERS

TO

PRESS

THE

PUSH

BUTTONS

.

N

EVER

USE

THE

COUNTERWEIGHT

PINCERS

OR

OTHER

POINTED

OBJECTS

.

4.2 -

AUTOMATIC DISTANCE AND DIAMETER GAUGE

Allows measuring the distance from the machine and the diameter at the point of application of the counterweight.
The same gauge allows proper positioning of the counterweights inside using the specifi c function

.

5

7

9

10

11

12

14

18

3

4

1

2

16

16

17

15

13

8

6

6

19

20