CEMB USA C211 (C) User Manual
Page 7

I 0147 -
6
I 0147 -
7
4
5
6
GB
GB
6 - Presetting of dimensions
6.1 - Automatic measurement
Two types of measurements are provided, namely:
- STANDARD WHEELS, valid also for correction modes ALU - 1-2
- ALU - S, very useful for alloy rims of special shape where ALU 2 does not guarantee sufficient approximation.
6.1.1 - Standard wheels
- Move the gauge into measuring position as shown in fig. 4. While the gauge is being displaced, the symbol shown in
fig. 5 appears on the display in movement thus indicating that the gauge is not in a steady position.
- Hold the gauge still in position for approx. 2 sec.
- Indication of successful memorization is displayed as shown in fig. 6.
- Return the gauge to position
0
.
- Manually preset the diameter and width dimensions as described in section
MANUAL PRESETTING
.
N.B.: If the symbol of fig. 5 or 6 appears on the displays, the gauge is not in position
0
. It is not possible to use the
control panel, not even for making a balancing spin. Check the position.