J&M GT460 User Manual
Page 27

Operators Manual
D3804 27
Setting/
Display
D.A.N Options
(
Bold
= Default)
Description
BUFFER
(
BUFFER
)
238
ON
Set to ON
PBLine
(PBLINE)
239 1,2,
3
Use 3
MENU 3
Display
Count
(
COUNT
)
301 .01,.02,.05,.1,.2,.5,
1,2,5,
10
,20,
50,100
Minimum weight change
that is displayed.
Note: If this is too small,
scale will be unstable.
Display Unit
(
LB-KG
)
303
LB
/KG
Unit of measure.
Note: If this changes,
calibration and set-up must
change.
Capacity
(
CAP
)
304
85,000
Maximum capacity of scale.
MENU 4
U-Alarm
(UALARM)
407
1
,2,3,4
Adjust unload alarm setting
CALIBRATION
Setup
Number
(
SETUP
)
871
Quick entry method selects
weigh method 1-4lbs, 5-
8kg, gain 1-9, display
counts 1-9 and capacity
*1000.
Calibration
Number
(
CAL
)
872
Weight displayed at .4mV/V
for these load cells.