Q.V.P. Es10 - Automatic Veneering User Manual
Quality vakuum products, inc, Es5 or es10 automatic set-up diagram, Automatic vakuum bag or frame press veneering
1.
Place the 3 prong plug from your Electric Pump into the 3 prong receptacle on the Electric
Controller.
2.
Remove Plastic Insert and Screw the Brass Filter Assembly (see diagram above) onto the
pump (IN) and tighten with a wrench. Do not tighten using the filter as leverage, or as a handle
since the filter may break. Also, check to make sure the filter bowl is tight. If not, remove it and
re-tighten, making sure it is on straight. If leakage is occurring in your system, this is the first
place to look. Remove Plastic Insert and screw black plastic muffler assembly into (OUT) port.
3.
If you purchased a complete system, a 10" length of ½" I.D. VAKuum Hose and a 5" length of
3/8" I.D. VAKuum Hose are supplied. A Plastic Tee and a Check Valve (placed inside the
longer hose) are also supplied. You must cut the larger hose (½" I.D.) to your desired length.
The piece that you cut off should now be connected to the other end of the tee, using the extra
Worm Clamp supplied. The other end of this piece of hose will be slipped over the brass nipple
on the VCA6, which is the brass bulk head fitting which connects to the base board of your
VAKuum Bag. Remember, when you cut this piece of hose, you must judge what length of
hose you want going from the tee to your bag. Refer to the diagram.
Once you have made the cut, you can now connect the remaining piece of ½" I.D. hose, with the
check valve inside, to the filter, which is now attached to your vacuum pump (step 2.) The red or
green end of the check valve should be towards the tee and vacuum bag.
The 5 foot length of 3/8" I.D. hose can now be attached from the tee to the barb on your Electric
Controller.
Filter
Electric Pump
Es5 or Es10 AUTOMATIC SET-UP DIAGRAM
AUTOMATIC VAKUUM BAG OR FRAME PRESS VENEERING
6/5/08 ES Automatic .cdr
Check Valve
(Red or green end towards
Bag/FP)
Quality VAKuum Products, Inc.
Or visit our site at
www.qualityvak.com
CALL 1-800-547-5484 TODAY!
Plastic
Tee
VAKuum Bag
or
Frame Press
VCA6
Electric Controller
1/2 I.D.
1/2 I.D.
3/8 I.D.
Foot Pedal
(Optional)
Electric
Outlet
OVER
NO
Remove orange plastic plug and screw in filter assembly.
Remove plastic cap
and screw in Black
Plastic Muffler
OUT
IN
74 Apsley St. - Hudson, MA 01749
Tel: 978-562-4680 - Fax: 978-562-4681