beautypg.com

Series 04 gear operator mounting and lubrication – Bray 4 Series User Manual

Page 3

background image

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written

consent of BRAY INTERNATIONAL, Inc.

The technical data herein is for general information only. Product suitability should be based solely upon customer’s detailed

knowledge and experience with their application.

Series 04 Gear Operator Mounting and Lubrication

Manual Number OM-04-001

Date: December 11, 2009 Page 3 of 4

Typical Properties

ASTM Test Method

Result

NLGI Grade Number

2

Soap Type

Lithium

Color

Brown

Mineral Oil Viscosity, SUS @ 210°F [100°C]

D2161

80

Penetration (Worked 60 Strokes)

D217

285

Dropping Point (Maximum Temperature)

D566

363°F [184°C]

Oil Separation

D1742

5.0%

Rust Preventative Test

D1743

Pass

Timken EP Test

D2509

45lbs [20.4kg]

Wheel Bearing Test (60mph [660rpm] @ 250°F [121°C] leakage) D1263

2.8gms

Oxidation Stability 100hrs, psi drop

D942

6

Water Washout Test (% loss @ 175°F [80°C], typ.)

D1264

7

1

National Lubricating Grease Institute

Adjustment of the “Open” position

travel stop:

Looking on the end of the gear operator the

left hand bolt is the open adjustment.

Remove the valve position indicator and view

the position of the valve stem.

We have to consider that in the full open posi-

tion the stem “double D” flats align with the

position of the valve disc. Similarly on the full

diameter stem the keyway position will align

with the valve disc position.

Loosen the lock nut and back off the open

travel stop screw one turn in the counter-

clockwise direction.

Rotate the hand-wheel until the sides of the

“double D” or the sides of the keyway are per-

pendicular with the face of the valve.

Rotate the open travel stop screw clockwise

until the screw touches the quadrant.

Verify that the “double D” or keyway is still

perpendicular to the valve face.

Carefully re-tighten the travel stop lock nut.

Replace the valve position indicator.

At this point apply a sealant to the lock nut of

the open travel stop to ensure that it will not

be readjusted.

Lubrication Procedures
These instructions are to be used during original assembly or during re-assembly after service for lubricat-

ing Series 04 worm gear operators. Proper lubrication is necessary to insure smooth operation and long

life of the unit. Failure to adhere to these instructions may lead to loss of performance or premature failure

of the operator.
I. Lubricant
The lubricant must be a high pressure or extreme pressure petroleum grease with a lithium based thick-

ener, which meets the NLGI grade 2. The grease must exhibit a high degree of tackiness or stringiness,

which enhances its ability to cling tenaciously to the lubricated surfaces.
The grease should meet the following specifications as a minimum. Any deviation below these specifica-

tions must be approved by the Bray USA Engineering Department.