B&K Precision 1823A - Manual User Manual
Page 5

5
1-2. Technical Specifications
INPUT A CHARACTERISTICS
FREQUENCY RANGE : 0.1 Hz to 100 MHz (DC Coupled)
30 Hz to 100 MHz (AC Coupled)
SENSITIVITY
: 0.1 Hz to 1 Hz: 250 mV
1 Hz to 100 MHz: 30 mV
COUPLING
: AC or DC Selectable
IMPEDANCE
: 1 M
Resistance, Shunted by < 40 pF
ATTENUATOR
: x 1 or x 10 Switch Selectable
LOW PASS FILTER
: -3 dB Point of 100 kHz, Switch Selectable
TRIGGER LEVEL
: + 350 mV to
– 350 mV (PRESET 0 V)
SLOPE
: Positive or Negative Slope Switch Selectable
* NOTE: Trigger error is typically
0.3 % of reading by the number of cycles
averaged for input signals having better than 40 dB S/N ratio and greater than
100 mV amplitude.
RESOLUTION AND NUMBER OF DISPLAYED DIGIT
Time Base Selector
INT
EXT
INT
EXT
INT
EXT
INT
EXT
Gate Time
0.01 S
0.1 S
1 S
10 S
Number Of Displayed Digit
5
6
6
7
7
8
8
9
Frequency (Input A,B)
RESOLUTION
0.1 Hz-0.99 Hz
10 uHz
1 uHz
1 uHz
0.1 uHz 0.1 uHz 10 nHz
10 nHz
1 nHz
1 Hz-9.9 Hz
0.1 mHz 10 uHz 10 uHz
1 uHz
1 uHz
0.1 uHz 0.1 uHz 10 nHz
10 Hz-99 Hz
1 mHZ
0.1 mHz 0.1 mHz 10 uHz
10 uHz
1 uHz
1 uHz
0.1 uHz
100 Hz-999 Hz
10 mHz 1 mHz
1 mHz
0.1 mHz 0.1 mHz 10 uHz
10 uHz
1 uHz
1 kHz-9.9 kHz
0.1 Hz
10 mHz 10 mHz 1 mHz
1 mHz
0.1 mHz 0.1 mHz 10 uHz
10 kHz-99 kHz
1 Hz
0.1 Hz
0.1 Hz
10 mHz 10 mHz 1 mHz
1 mHZ
0.1 mHz
100 kHz-999 KHz
10 Hz
1 Hz
1 Hz
0.1 Hz
0.1 Hz
10 mHz 10 mHz 1 mHZ
1 MHz-9.9 MHz
100 Hz
10 Hz
10 Hz
1 Hz
1Hz
0.1 Hz
0.1 Hz
10 mHz
10 MHz-99 MHz
1 KHz
100 Hz 100 Hz
10 Hz
10 Hz
1 Hz
1 Hz
0.1 Hz
100 MHz
10 KHz
1 KHz
1 KHz
100 Hz
100 Hz
10 Hz
10 Hz
1 Hz
ACCURACY
:
0.1Hz to 100 Hz : ± Time base error ± resolution ± 1 count
101Hz to 100MHz: ± Time base Error ± 1 count ± (Resolution Table 1 x 20)
PERIOD RANGE
: 10 nS to 10 S
DISPLAY
: n. u. m., Sec with decimal point
TOTAL RANGE
: DC to 30 MHz
CAPACITY
: 0 to 999 999 999
OVER FLOW
: “OF”