B&K Precision 307A - Manual User Manual
Page 13
10.6 Low ohms measurement 0 - 3W
Always check for voltage before testing and
measuring on a circuit. This instrument is intended
for measuring Low W and Insulation resistance on
un-energized circuits only.
Use the procedure explained at points 7.2, 7.3, 7.4.
The first procedure to follow, is to zero the test leads
and the fuse resistance.
The instrument is equipped with a Zero W Knob.
First, short circuit the test leads by connecting them
together, then, press the test button and adjust the
Zero W knob until the pointer is precisely on the "0"
of the 3W scale. Use the mirror scale to be precise
with the pointer.
Connect the test leads to the circuit
to be measured.
For short test, press button and keep
pressed.
For long test or hand free Measurements, press and
turn the test button.
-11-
N-E
P-E
!
FOR CONTINUOUS
TESTING, PRESS AND TURN
LOCK
!
FOR Vac: DO NOT PRESS
PRESS TO TEST
Batt. Check
3W
500W
250V/100MW
500V/200MW
1000V/400MW
INSULATION
MW
W
CONTINUITY
0W
ZERO
ADJUST
OHM
- 2530B - Manual (191 pages)
- 2530B - Datasheet (4 pages)
- 2120C - Manual (30 pages)
- 2100C Series - Datasheet (2 pages)
- 2120B - Datasheet (1 page)
- 2540B - Manual (250 pages)
- 2540B - Datasheet (6 pages)
- 2511 - Manual (159 pages)
- 2510 Series - Datasheet (7 pages)
- 2552-2559 - Manual (159 pages)
- 2550 Series - Datasheet (6 pages)
- 2552-2559 - Programming Manual (140 pages)
- 2405A - Datasheet (1 page)
- 2703C - Manual (5 pages)
- 2703C - Datasheet (2 pages)
- 2704C - Manual (5 pages)
- 2704C - Datasheet (2 pages)
- 2705B - Manual (5 pages)
- 2705B - Datasheet (2 pages)
- 312B - Datasheet (1 page)
- 2706B - Manual (5 pages)
- 2706B - Datasheet (2 pages)
- 2707B - Manual (5 pages)
- 2707B - Datasheet (2 pages)
- 2708B - Manual (5 pages)
- 2708B - Datasheet (2 pages)
- 330B - Datasheet (2 pages)
- 2709B - Manual (5 pages)
- 2709B - Datasheet (2 pages)
- 2860A - Datasheet (1 page)
- 2712 - Manual (5 pages)
- 2712 - Datasheet (2 pages)
- 388B - Datasheet (2 pages)
- 392 - Manual (31 pages)
- 2831E - Manual (78 pages)
- 2831E - Datasheet (5 pages)
- 5492B - Manual (111 pages)
- 5492B - Datasheet (5 pages)
- 815 - Datasheet (1 page)
- 875B - Datasheet (1 page)
- 890C - Manual (113 pages)
- 890C - Datasheet (3 pages)
- 875B - Manual (37 pages)
- 878B - Manual (104 pages)
- 878B - Datasheet (4 pages)