Multimeter and Recorder Specifications
■
All specifications are based on operating at temperatures 23 ± 5°C and relative humidity < 75%.
■
Accuracy is based on ± (% of reading + offset).
Multimeter
Display Resolution
6000 counts
Measurement Function
DC voltage, AC voltage, resistance,
diode, continuity, capacitance,
DC current, AC current
Max. Input Voltage
AC: 750 V (20 Hz - 1 kHz)
DC: 1000 V
Max. Input Current
(1)
AC: 10 A (20 Hz - 1 kHz)
DC: 10 A
Input Impedance
10 MΩ
Max. Input Voltage
Between Multimeter
Input Reference
and Ground
CAT II 600 V
CAT III 300 V
DC Voltage
Range
Resolution
Accuracy
60.00 mV
10 µV
± (1 % + 15 digits)
600.0 mV
100 µV
± (1 % + 5 digits)
6.000 V
1 mV
60.00 V
10 mV
600.0 V
100 mV
1000 V
1 V
AC Voltage
(2)
Range
Resolution
Accuracy
60.00 mV
10 µV
± (1 % + 15 digits)
600.0 mV
100 µV
± (1 % + 5 digits)
6.000 V
1 mV
60.00 V
10 mV
600.0 V
100 mV
750 V
1 V
Multimeter (cont.)
Resistance
Range
Resolution
Accuracy
600.0 Ω
0.1 Ω
± (1 % + 5 digits)
6.000 kΩ
1 Ω
60.00 kΩ
10 Ω
600.0 kΩ
100 Ω
6.000 MΩ
1 kΩ
60.00 MΩ
10 kΩ
Diode and Continuity Measure
Diode
0 – 2 V
Continuity
< 50 Ω alarm
Capacitance
Range
Resolution
Accuracy
40.00 nF
10 pF
± (3 % + 10 digits)
400.0 nF
100 pF
± (4 % + 5 digits)
4.000 µF
1 nF
40.00 µF
10 nF
400.0 µF
100 nF
DC and AC Current
(3)(4)
Range
Resolution
Accuracy
60.00 mA
10 µA
± (1 % + 5 digits)
600.0 mA
100 µA
6.000 A
1 mA
± (1.5 % + 5 digits)
10.00 A
10 mA
Recorder
Scope Trend Plot
Display Mode
Full view, Normal
Record Length
800k points, > 24 hours
Number of Channels
2
Multimeter Trend Plot
Display Mode
Full view, Normal
Record Length
1.2M dots, > 24 hours
Number of Channels
1
Scope Recorder
Display Mode
Full view, Normal
Max. Record Length
Single Channel: 7 M pts
Dual Channel: 3.5 M pts
Number of Channels
2
Maximum Record Size to
External Storage
4 GB, 3000 hours
(1) Current input terminals protected with internal 250 V rated fuse.
(2) For frequency range 20 Hz to 1 kHz.
(3) For 10 A terminal, > 6 A DC or AC rms for 10 seconds ON and 15 minutes OFF.
(4) For AC current ranges, frequency is verified for 20 Hz to 1 kHz.
v040714
Included Accessories
User manual, passive probes (one per channel), pair of DMM test leads, 7.4 V Li-ion
battery BP2510, USB cable, probe compensation connector, AC power adapter,
travel hard case LC2510 (models 2515 and 2516 only), and certificate of calibration