TIME INTERVAL ANALYZER & UNIVERSAL COUNTERS
TA320
Specifications
0 to 360 degrees (where, A to B: MIN (71 ns); B to A: 30 ns min.)
0.01 degree
±
measured A-to-B interval + | A-to-B interval resolution |
measured phase difference
measured A-input period –
√
2
×
| A-to-B interval resolution |
±
measured A-to-B interval + | A-to-B interval resolution |
measured phase difference
measured A-input period –
√
2
×
| A-to-B interval resolution |
( )
( )
Specifications
Specifications
0 to 99.999% (pulse width: 71 ns to 100 ms)
The larger value, either 0.001% or
loops
×
100%
Period
±
measured pulse width + | pulse-width resolution |
– measured duty ratio
measured period –
√
2
×
| pulse-width resolution |
±
measured pulse width + | pulse-width accuracy |
– measured duty ratio
measured period –
√
2
×
| pulse-width accuracy |
*
1
: The value when, under the reference operating conditon, the warm-up time has expired.
*
2
: The value when the period of a 1-MHz sine wave is measured with an event size of 1000.
Item
Measuring range
Display resolution
Resolution*
1
Accuracy*
1
Trigger slopes
Time stamp mode
30 ns to 100 ms
100ps
±
300 ps rms
±
√
2
×
trigger error
● Period
Specifications
Hardware histogram mode
30 ns to 3.2
µ
s
The larger value, either 100 ps or the histogram span setting
200
The larger value, either
±
300 ps rms or display resolution,
±
√
2
×
trigger
error
±
300 ps rms
±√
2
×
trigger error
±
(timebase frequency stability
×
measured period)
±
300-ps systematic error
Item
Measuring range
Display resolution
Resolution*
1,
*
3
Accuracy*
1
Trigger slopes
Time stamp mode
30 ns to 100 ms
100 ps
±
300 ps rms
±
rising trigger error
±
falling trigger error
22T*
4
● Pulse Width
Specifications
Hardware histogram mode
30 ns to 3.2
µ
s
The larger value, either 100 ps or the histogram span setting
200
The larger value, either
±
300 ps rms or display resolution,
±
rising trigger error
±
falling trigger error
±
300 ps rms
±
(timebase frequency stability
×
measured pulse width)
±
trigger level timing error
±
1-ns systematic error
( )
( )
Item
Measuring range
Display resolution
Resolution*
1
Accuracy*
1
Trigger slopes
● Duty Ratio (time stamp mode only)
Item
Measuring range
Display resolution
Resolution*
1,
*
5
Accuracy*
1
Trigger slopes
Conditon for continuous
measurement*
6
Time stamp mode
5 ns to 100 ms
100 ps
±
300 ps rms
±
A-input trigger error
±
B-input trigger error
● A-to-B Interval
Specifications
Hardware histogram mode
5 ns to 3.2
µ
s
The larger value, either 100 ps or the histogram span setting
200
The larger value, either
±
300 ps rms or the display resolution,
±
A-input trigger error
±
B-input trigger error
Item
Measuring range
Display resolution
Resolution*
1
Accuracy*
1
Trigger slopes
Time stamp mode
A to B: 30 ns to 100 ms; B to A: 30 ns to 100 ms
100 ps
±
300 ps rms
±
A-input trigger error
±
B-input trigger error
● A-to-B-to-A Interval
±
300 ps rms
±
(timebase frequency stability
×
measured A-to-B-to-A interval)
±
trigger level timing error
±
1-ns systematic error
Item
Measuring range
Display resolution
Resolution*
1
Accuracy*
1
Trigger slopes
● Phase Difference (time stamp mode only)
Hardware histogram mode
A to B: 30 ns to 3.2
µ
s; B to A: 30 ns to 3.2
µ
s
The larger value, either 100 ps or the histogram span setting
200
The larger value, either
±
300 ps rms or display resolution,
±
A-input trigger error
±
B-input trigger error
A
B
B
A
A
B
A
B
B
A
B
A
A
A
A
A
A
A
A
A
B
B
B
B
A
A
B
B
A
B
A
B
±
300 ps rms
±
(timebase frequency stability
×
measured A-to-B interval)
±
trigger level timing error
±
1-ns systematic error
The B-to-A interval must be greater than 30 ns.