Options SD and HD Video Measurements (Continued)
Characteristic
Description
Sync Measurement
Accuracy
Sync Amplitude
±2 mV ±1.5% of reading
Blanking interval measurements, including
sync amplitude, width and rise time
Sync Timing
(0.06/sample rate + 15 ppm x |Reading|) RMS
Rise Time and Fall Time
±5 ns
Channel Delay
CH 1 to CH 2, CH 1 to CH 3, CH 2
to CH 3; readouts in ns
Range
Accuracy
Measurement
±35 ns
±5 ns
Delay Match Error
Less than 1 ns
Any two channels
Option VGA Video Measurements
*2
Characteristic
Accuracy
Description
Amplitude Measurements
Luma Level, Max and Min
±8 mV ±2.0% of reading
VESA 6.1
Color Bars
±3 mV ±1.8% of reading
Channel voltage levels measured relative to back porch
Ch-Ch Mismatch (mV)
±3 mV ±3.6% of reading
32-step staircase signal. VESA 6.5 Channel
voltage levels measured relative to back porch
Ch-Ch Mismatch (%)
±0.4% ±(3.6%) x (Luma Level)/(Max
Luma Level); maximum ±4%
H & V sync Logic “0” and “1”
± [8mV ±(0.0085) x (p-p sync amplitude)] ±1.8%
VESA 7.1
(p-p sync amplitude)=(logic 1 voltage)–(logic 0 voltage)
Linearity, Resolution, Monotonicity
Integral Linearity (%)
±2%
VESA 6.4. Requires step response compliant
Differential Linearity
±0.25 LSB (8 bit)
to VESA limits for overshoot/undershoot,
±0.5 LSB (10 bit)
amplitude and settle time
RGB Video Monotonicity
±0.25 LSB (8 bit)
Monotonicity checks every step on the ramp
±0.5 LSB (10 bit)
to ensure signal is always rising
Resolution Measurement Range
5 to 10 bits
Resolution measured in bits
HV Sync Monotonic Rise and Fall
Detects monotonicity errors as small as 1%
Checks sync for always rising and always-
of p-p sync amplitude
falling characteristic. Requires VESA compliant
amplitude, noise, rise and fall
Noise
Noise (mV) Measurement Range 8 to 15 mV
±5.25 mV
Noise (mV) Measurement Range 15 to 25mV
The lesser of ±7 mV or ±35%
Noise Injection Ratio (%) Measurement
Range 1.1% to 2.1%
±.75%
Noise Injection Ratio (%) Measurement
Range 2.1% to 3.6%
±1%
Timing
Channel Skew Measurement Range ±35 ns
±500 ps
Alternate implementation of VESA 6.7; Any two channels
H Timing (ns) – Front and Back Porch, Left
360 ps ±15 ppm x Reading
and Right Border, Addressable Video
H Sync Period, H and V Sync Pulse width (ns)
80 ps ±15 ppm x Reading
V Sync Period (µs)
20 ns ±15 ppm x Reading
Read out (precision) is 1 µs
Measurement of RGB noise on constant pedestal,
0 to 700 mV. Output in mV peak to peak, dB below
700 mV, VESA Sec 6.6. Displayed value corrected for
instrument noise. Specification applies with 500 MHz
bandwidth filter and 10 averages selected