Sr785 specifications – Atec Stanford-Research-Systems-SR785 User Manual
Page 7
Min. tach pulse width
100 ns
Max. tach pulse rate
750 kHz
Transient Capture
Mode
Continuous data recording
Maximum rate
262,144 samples/s for both inputs
Maximum capture
2 Msamples (single input)
length
8 Msamples with optional memory
Octave Analysis
Standards
Conforms to ANSI std. S1.11-1986
Order 3 Type 1-D and IEC 225-1966
Frequency range
(Band centers)
Single channel
1/1 Octave
0.125 Hz to 32 kHz
1/3 Octave
0.100 Hz to 40 kHz
1/12 Octave
0.091 Hz to 12.3 kHz
Two channels
1/1 Octave
0.125 Hz to 16 kHz
1/3 Octave
0.100 Hz to 20 kHz
1/12 Octave
0.091 Hz to 6.17 kHz
Accuracy
<0.2 dB (1 second stable average,
single tone at band center)
Dynamic range
80 dB (1/3 Octave, 2 second stable
average) per ANSI S1.11-1986
Sound level
Impulse, Peak, Fast, Slow and L
eq
per ANSI S1.4-1983 Type 0 and
IEC 651-1979 Type 0
Order Tracking
Delta order
0.0075 to 1
Resolution
up to 400 lines
Amplitude accuracy
±1 dB (typ.)
Displays
Order map (mag. and phase), order
track (mag. and phase), orbit
Curve Fit and Synthesis
Type
20-pole/20-zero curve fit
(non-iterative rational fraction)
Order selection
Auto or manual
Output format
Pole-zero, polynomial, pole-residue
Source Output
Amplitude range
0.1 mVp to 5 Vp
Amplitude resolution
0.1 mVp
DC offset
<10.0 mV (typ.)
Offset adjust
±5 VDC (sine, swept-sine, two-tone)
Output impedance
<5
Ω
, ±100 mA peak output current
Sine Source
Amplitude accuracy
±1 % of setting, 0 Hz to 102.4 kHz
0.1 Vp to 5 Vp into Hi-Z load
Harmonics, sub-harm. 0.1 Vp to 5 Vp
& spurious signals <
−
80 dBc (fundamental <30 kHz)
<
−
75 dBc (fundamental <102 kHz)
Two-Tone Source
Amplitude accuracy
±1 % of setting, 0 Hz to 102.4 kHz,
0.1 Vp to 5 Vp into Hi-Z load
Harmonics, sub-harm. <
−
80 dBc, 0.1 Vp to 2.5 Vp
White Noise Source
Time Record
Continuous or burst
Bandwidth
DC to 102.4 kHz or limited to span
Flatness
<0.25 dBpp (typ.), 5000 rms
averages (<1.0 dBpp (max.))
Pink Noise Source
Bandwidth
DC to 102.4 kHz
Flatness
<2.0 dBpp, 20 Hz to 20 kHz (meas-
ured using averaged 1/3 oct. analysis)
Chirp Source
Time record
Continuous or Burst
Output
Sine sweep across the FFT span
Flatness
±0.25 dB (1.0 Vp)
Swept-Sine Source
Auto functions
Source level, input range and
frequency resolution
Dynamic range
145 dB
Arbitrary Source
Amplitude range
±5 V
Record length
2 Msamples (playback from arbitrary
waveform memory or capture buffer),
variable output sample rate
General
CRT monitor
Monochrome, 800H by 600V res.
Interfaces
IEEE-488.2, RS-232 and printer
interfaces (standard). All instrument
functions can be controlled through
computer interfaces. A PC (XT)
keyboard input is provided for
additional flexibility.
Hardcopy
Print to dot matrix and PCL
compatible printers. Plot to HP-GL
or postscript plotters. Print/plot to
RS-232 or IEEE-488.2 interfaces or
disk file. Additional file formats
include GIF, PCX and EPS.
Disk
3.5" DOS format, 1.44 Mbytes
Preamp power
Power connector for SRS preamps
Power
70 W, 100/120/220/240 VAC,
50/60 Hz
Dimensions 17"
Ч
8.25"
Ч
24" (WHD)
Weight
56 lbs.
Warranty
One year parts and labor on defects
in materials and workmanship
SR785 Specifications
Stanford Research Systems
phone: (408)744-9040