beautypg.com

Model 296, Ordering information – Atec Wavetek-295-296 User Manual

Page 5

background image

9

Adjustable threshold -10 V to 10 V.

Reference: Accepts external 10 MHz reference

signal.

System Outputs

Reference: Accepts external 10 MHz reference

signal.

Horizontal Sweep: 0 to 10 V ramp proportional to

sweep frequency between start and stop limits.

Z-Axis: Oscilloscope intensity modulation. Used

for waveform editing on an oscilloscope.

Channel Inputs

Trigger: TTL level.

AM Modulation: Used for amplitude and

suppressed carrier modulation.

Clock: External signal’s frequency used as

sampling frequency for arbitrary waveforms.

Channel Outputs

Main: Outputs waveform.

Clock: TTL signal. Frequency range 0.2 Hz to

100 MHz.

Digital (Model 296 only): 16-bit differential ECL

updated at up to 50 MHz.

Segment (Model 296 only): This output is setup to

be used as a source for the AM input.

Sync: TTL signal output synchronous with the main

output waveform.

Posn: TTL level position markers placed at user

selected waveform points.

General

Dimensions: 42.5 cm (16.75 in) wide; 13.3 cm

(5.22 in); 54.1 cm (17.8 in) deep.

Weight: 18 kg (40 lb.)

Power: 85 to 270 Vac. 60 VA plus 60 VA per

channel.

Operating Temperature: 0

°

C to 50

°

C. 10

°

C for

specified operation.

Display: 5 in, 320 x 200 pixel, LCD screen.

Ordering Information

Model 296: 50 MHz Arbitrary Waveform Generator.

Includes 1 arb channel with 128k waveform memory,

DOS compatible 3 1/2 inch floppy disk drive.

Model 296-EM512: 50 MHz Arbitrary Waveform

Generator. Includes 1 arb channel with 512k

waveform memory, DOS compatible 3 1/2 inch floppy

disk drive.

Option 001: Additional arb channel with 128k

waveform memory.

Option 001-EM512: Additional arb channel with

512k waveform memory.

Note: Up to three additional arb channels can be

Model 296

added to the basic model for a total of four arb

channels. 128k and 512k channels may be installed

in the same chassis.

Option 004: Rack mount kit for a standard 19 inch

rack.

Option 005: Direct DSO download of waveforms

from selected digital oscilloscopes via a GPIB cable.

Option 007: High Voltage and External Summing

module. Increases the output for up to three arb

channels to 100 Vpp (into 500

). Amplitude of each

channel is independently programmed. Provides an

input for summing an external signal.

Maximum Slew: 200 V/s

Maximum Bandwidth: 1 MHz (sampling

frequency)

NOTE: Model 296 is limited to 3 arb channels when Option 007 is
installed.

Model 485: WaveForm DSP; Windows based

software for creating and editing complex

waveforms.

Model 295: 50 MHz Arbitrary Waveform Generator

(1 channel w/32k memory and Floppy Disk Drive)

Model 295-EM: 50 MHz Arbitrary Waveform

Generator (1 channel w/128k memory and Floppy

Disk Drive)

296,295 Comparison Chart

296

295

Waveform Memory

128k (512k opt.)

32k (128k/512k opt.)

Maximum Sequencing Segments

4,096

4

Frequency Control of Segments

yes

no

16 Bit Digital Output

yes

no

Model 295 EM512: 50 MHz Arbitrary Waveform

Generator (1 channel w/512k memory and Floppy

Disk Drive)

Option 001: Additional 50 MHz Arb Channel with

32k memory

Option 001-EM: Additional 50 MHz Arb Channel

with 128k memory

Option 001-EM512: Additional 50 MHz Arb

Channel with 512k memory

Option 004: Rack Mount Kit for a standard 19 inch

rack

Option 005: Direct DSO Waveform Transfer

Option 007: High Voltage Module

Model 485: Waveform DSP Arbitrary Waveform

Creation Software

Note: Model 295 is limited to 3 arb channels when Option 007 is
installed