Characteristics

Vertical System Analog Channels

Characteristic

MSO3012

DPO3012

MSO3014

DPO3014

MSO3032

DPO3032

MSO3034

DPO3034

MSO3054

DPO3054

Input Channels

2

4

2

4

4

Analog Bandwidth (-3 dB)

100 MHz

100 MHz

300 MHz

300 MHz

500 MHz

Calculated Rise Time

5 mV/div (typical)

3.5 ns

3.5 ns

1.17 ns

1.17 ns

700 ps

Hardware Bandwidth Limits

20 MHz

20 MHz, 150 MHz

Input Coupling

AC, DC, GND

Input Impedance

1 MΩ ±1%, 75 Ω ±1%, 50 Ω ±1%

Input Sensitivity Range, 1 MΩ

1 mV/div to 10 V/div

Input Sensitivity Range, 75 Ω, 50 Ω

1 mV/div to 1 V/div

Vertical Resolution

8 bits (11 bits with Hi Res)

Maximum Input Voltage, 1 MΩ

300 V

RMS

with peaks ≤ ±450 V

Maximum Input Voltage, 75 Ω, 50 Ω

5 V

RMS

with peaks ≤ ±20 V

DC Gain Accuracy

±1.5% for 5 mV/div and above

±2.0% for 2 mV/div

±2.5% for 1 mV/div

Channel-to-Channel Isolation

(Any Two Channels at Equal Vertical Scale)

≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated BW

Offset Range

Range

1 MΩ

50 Ω, 75 Ω

1 mV/div to 99.5 mV/div

±1 V

±1 V

100 mV/div to 995 mV/div

±10 V

±5 V

1 V/div

±100 V

±5 V

1.01 V/div to 10 V/div

±100 V

NA

Vertical System Digital Channels

Characteristic

All MSO3000 Models

Input Channels

16 Digital (D15 to D0)

Thresholds

Threshold per set of 8 channels

Threshold Selections

TTL, CMOS, ECL, PECL, User Defined

User-defined Threshold

Range

-15 V to +25 V

Maximum Input Voltage

-20 V to +30 V

Threshold Accuracy

±(100 mV +3% of threshold setting)

Maximum Input Dynamic

Range

50 V

pk-pk

(threshold setting dependent)

Minimum Voltage Swing

500 mV

pk-pk

Input Impedance

101 kΩ

Probe Loading

8 pF

Vertical Resolution

1 bit

Horizontal System Analog Channels

Characteristic

All MSO3000 Models
All DPO3000 Models

Maximum Sample Rate

(all channels)

2.5 GS/s

Maximum Record Length

(all channels)

5 Mpoints

Maximum Duration of

Time Captured at Highest

Sample Rate

(all channels)

2 ms

Time-base Range (s/div)

1 ns to 1000 s

Time-base Delay Time

Range

-10 divisions to 5000 s

Channel-to-Channel

Deskew Range

±100 ns

Time-base Accuracy

±10 ppm over any ≥1 ms interval

Horizontal System Digital Channels

Characteristic

All MSO3000 Models

Maximum Sample Rate

(Main, all channels)

500 MS/s (2 ns resolution)

Maximum Record Length

(Main, all channels)

5 Mpoints

Maximum Sample Rate

(MagniVu, all channels)

8.25 GS/s (121.2 ps resolution)

Maximum Record Length

(MagniVu, all channels)

10 kpoints centered on the trigger

Minimum Detectable

Pulse Width

2.0 ns

Channel-to-Channel

Skew

500 ps typical

www.tektronix.com

11