beautypg.com

Atec Tektronix-TDS500D-700D Series User Manual

Page 3

background image

COMPLEMENTARY
MEASUREMENT
ACCESSORIES
Tektronix provides a wide
range of measurement acces-
sories optimized for the TDS
family. These accessories are
designed to operate via the
TEKPROBE

®

interface, which

provides power and auto-
matic scaling, to complete the
DPO measurement solutions.
Active Probes such as the P6217
and P6245 active probes were
designed specifically for the
DPO products. For example,
the P6217 is capable of
achieving the full 2 GHz
bandwidth on a TDS 794D,
while providing low loading.
The P6339A Buffered Passive
Probe
is designed to provide
high impedance 500 MHz
general purpose probing
capabilities for the TDS 794D.
Optical-to-Electrical Converters
(P6701B, P6703B)
allow conve-
nient analysis of optical
transmission signals with the
oscilloscope to standard
wavelengths for SONET/SDH
and Fibre Channel.
High-bandwidth Differential
Probes (P6246, P6247)
enable
high bandwidth (up to 1 GHz)
differential measurements
while maintaining high com-
mon-mode rejection.

Current Probes such as the
TCP202 and High-Voltage Dif-
ferential Probes
such as the
P5205 and P5210 allow safe,
high-power measurements.
Direct Probe Readouts use
information from the probes
to display measurements in
units of Amps, Volts, and
Watts.

SOPHISTICATED DOCUMENTATION
Save screen displays in a
number of standard desktop
publishing formats to the
internal 3.5 in. DOS-compati-
ble floppy disk drive. Trans-
fer the disk to a PC for import
into word processing applica-
tions. Make hardcopies
directly to monochrome or
color printers and plotters
connected to the computer
network (LAN), GPIB, RS-
232, or Centronics ports, or
acquire waveforms, screen
displays, and scope settings
using Tektronix WaveStar

software running on a PC
interfaced to the GPIB port.

page 3

The horizontal histogram of the selected region of the
waveform shows the character of a metastable flip-flop
output.

A SONET/SDH (OC-3/STM-1) signal is compared with
the standard mask, showing a compliant waveform.

TDS 500D/700D Series Timebase System

TDS 794D

TDS 784D/TDS 580D

TDS 754D / TDS 724D /

TDS 540D/TDS 520D

Time Bases

Main, delayed

Main, delayed

Main, delayed

Time Base Range

200 ps to 10 s/div

200 ps to 10 s/div

500 ps to 10 s/div

Time Base Accuracy

±25 ppm

±25 ppm

±25 ppm

(over any interval

1 ms)

(over any interval

1 ms)

(over any interval

1 ms)

Pre-trigger Position

0% to 100%

0% to 100%

0% to 100%

of any record

of any record

of any record

Delay Between Channels

50 ps (any 2 channels with equal V/div and coupling)