Conducted emc test system, System 2050 – Atec Teseq-Schaffner-NSG2050 User Manual
Page 3
Conducted EMC Test System
Technical Specifications
2050 / 2051 / 2052 / 2056 / NSG 642
xx
PNW 2050
Hybrid pulse
1.2/50µs - 8/20µs, 200V to 6600V
up to 3300A
Impedance
2
Ω
an 12
Ω
Pulse rep
10s to 10000s
PNW 2051
Telecom
10/700µs and 0.5/700µs, 200V to 6600V
up to 440A
Impedance
15
Ω
and 40
Ω
Pulse rep
10s to 10000s
PNW 2052
Ring wave
0.5µs/100kHz, 200V to 6600V
up to 550A
Impedance
12
Ω
, 30
Ω
and 200
Ω
Pulse rep
10s to 10000s
PNW 2056
Damped osc.
0.5µs/100kHz up to 4000V
75ns/100kHz up to 2700V
75ns/1MHz up to 2700V
Rep rate
40Hz at 100kHz, 400Hz at 1MHz
NSG 642
Power quality
motor driven transformer extension
1 to 280Vac
16A continuous, 25A for 1min.
Speed
up to 120V/s
mechanical
310 x 449 x 510, 35kg approx
PNW 2050
provides high energy hybrid surge pulses
of 1.2/50µs - 8/20µs with an extended
voltage range as required by IEC, ANSI-
IEEE and many other standards. It is
used with single- and 3-phase power-line
coupling networks or data-line couplers.
The network can also be used, in
conjunction with an antenna, for pulsed
magnetic field testing, e.g. to
IEC 61000-4-9.
PNW 2051
provides a 10/700µs pulse, as specified in
telecom applications and also required in
some industrial electronics standards, e.g.
IEC 61000-4-5. For higher test
specifications, PNW 2051 also provides
the sharper pulse rise time of 0.5µs. The
matching pulse networks, required in
some applications, are available.
PNW 2052
generates a 100kHz ringwave, as required
by the ANSI-IEEE standard. It can be
used with external coupling unit CDN 131
or CDN 133 for single-or three-phase
testing up to 25A.
PNW 2056
is a high frequency pulse generator which
produces damped oscillatory waves of
100kHz and 1MHz with amplitudes up to
4kV.
Coupling Units
A comprehensive range of couplers and
extension units is available for single- and
three-phase power-line and data-line
testing. Full technical details are outlined
on page 44.
CDN 131 and CDN 151
are designed to couple surge pulses and
fast transient pulses respectively to
single-phase power lines. They can be
used with all the surge and fast transient
pulse generator networks, for testing up
to 240Vac and 25A.
CDN 133 and CDN 153
are providing three-phase coupling for
tests up to 440Vac (phase to phase) and
25A continuous operation.
All combinations of coupling modes are
selectable under software control. There
are separate inputs for high energy surge
pulses and high frequency burst pulses
with one common output to the
equipment under test.
NSG 642
is an automated variable AC source which
can be used as a second supply with the
drop-out simulator PNW 2003 to generate
a wide range of dynamic voltage
variations including over-voltage, ramps
and dips. Meets the requirements of
IEC 61000-4-11.
Technical Specifications
CDN 131 / 133
xx
CDN 131
Surge Coupling single-phase coupling network
20V to 230Vac, 50/60Hz
25A continuous, 30A for 0.5 hour
Burst Coupling
CDN 151 option
Mechanical
310 x 449 x 510, 22kg approx
CDN 133
Surge Coupling 3-phase coupling network
3 x 20V to 440Vac, 50/60Hz
25A continuous, 30A for 0.5 hour
Burst Coupling
CDN 153 option, 3-phase
Mechanical
310 x 449 x 510, 32kg approx
System 2050