Atec Zimmer-LMG450 User Manual
Page 3
Ch 1
Ch 2
Ch 3
Ch 4
4Ø 4W / 4Ø 5W
1Ø 2W
1Ø 2W
1Ø 2W
1Ø 2W
3Ø 3W / 3Ø 4W / 4Ø 4W
1Ø 2W
3Ø 3W (Aron)
3Ø 3W (Aron)
3Ø 3W (Aron)
1Ø 2W
1Ø 2W
Device
Measured Value
Ch 1
Ch 2
Ch 3
Ch 4
Appropriate setting
of wiring
4Ø motors
Power of all windings
Phase 1
Phase 2
Phase 3
Phase 4
4+0
High power batterie
chargers (3Ø -> DC)
Input and output
power, efficiency
Phase 1
Phase 2
Phase 3
DC-Out
3+1
(UD I* -> U* I*)
Rectifier section of
inverters (3Ø -> DC)
Input power,
rectifier efficiency
Phase 1
Phase 2
Phase 3
DC-Bus
3+1
(UD I* -> U* I*)
Output section of
inverters (DC -> 3Ø)
Output power,
chopper efficiency
AC-Out 1 AC-Out 2 AC-Out 3
DC-Bus
3+1
(UD I* -> UD ID)
1Ø -> 3Ø inverter
Low power motor
drives
Input and output
power, efficiency
AC-Out 1 AC-Out 2 AC-Out 3
Phase 1
3+1
(UD I* -> U* I*)
Power supplies with
multiple outputs
Input and output
power, efficiency
DC-Out 1 DC-Out 2 DC-Out 3
Phase 1
3 +1
1Ø Transformers with
multiple output
windings
Input and output
power, efficiency
AC-Out 1 AC-Out 2 AC-Out 3
AC-In
3+1
3Ø laods with auxiliary
supplies
Complete input power
Phase 1
Phase 2
Phase 3
Aux. AC
or DC
3+1
(UD I* -> UD ID)
3Ø -> 3Ø inverter
High power motor
drives
Input and output
power, efficiency
AC-In 1
AC-In 2
AC-Out 1 AC-Out 2
2+2
(UD I* -> UD ID)
3Ø -> 1Ø
AC power source
Input-, output- and
DC-Bus power,
efficiency
AC-In 1
AC-In 2
DC-Bus
AC-Out
2+2
(UD I* -> U* I*)
4mm safety sockets
600V CAT III
Direct measurement
Standard current clamps
with current outputs >0.5A
Compensated
ZES current clamps
HD15 sockets
for external sensors
Magneto-resistive
current transducer modules
PSU200/400/600/700
Precision current transducer
Standard current clamps with
voltage/current (<0.5A)
outputs
Hall effect transducers
DC/AC current clamps with
voltage output
e.g. for oscilloscopes
0.6 ... 16A (6 Ranges)
DC ... 20 kHz
100A ... 3000A
45Hz ... 3kHz
1.2A ... 40A (6 Ranges)
5Hz ... 20kHz
5A ... 50A
DC ... 20KHz
1A ... 700A
peak
DC ... 20kHz
(300kHz, bandwidth of sensor
is limited by LMG450)
10A ... 200A
45Hz ... 3kHz
5A ... 200A
DC ... 20kHz
10A ... 200A
DC ... 20kHz
Compensated current clamp
Part No. L45-Z06
A special current measuring device is the
compensated current clamp by ZES ZIMMER.
It features electronic compensation of amplitude
and delay errors. Even at low current levels of
1A to 40A, measurement is exact in the frequency
range from 5Hz to 20kHz. Due to its high dynamic
common-mode rejection, this current clamp is also
very suitable for carrying out measurements at the
frequency inverter output.
Compensated current clamp L45-Z06
Various methods of applying current to be measured
4 independent power measuring channels
The current and voltage paths
of the four power measuring
channels are all isolated from
each other and from earth.
This allows a high degree of
measuring freedom in many
different power measurement
applications.
The adjacent table shows vari-
ous types of wirings for grouped
and individual measurement
channels. The table also assigns
application examples for the
respective types of wiring.
Power measurement channels
1 and 4 can each be synchro-
nised to their input signals
(fundamental waves etc.)
independent of each other.
Channels 1 and 4 are then the
synchronisation references for
the other channels contained in
groups A and B.
This is a very useful method for
carrying out efficiency measure-
ments for equipment where the
input and output have different
frequencies, for example a
3-phase frequency inverter with
single-phase mains supply.
Wiring settings in () are featured
by option „Star-Delta Conversion“
Group A
Group B