A d v a n c e d Te s t S o l u t i o n s f o r E M C
ProfLine 2100-1
ProfLine 2100-3
System contents
CCN 1000-1 1-phase
CCN 1000-3 1-phase
coupling unit
coupling unit
DAQ card
DAQ card
Interface cable
Interface cable
WIN 2100 test software
WIN 2100 test software
Coupling unit
Number of phases
1
3
Measurement channels
4
12
EUT connector: Front panel
CEE 77
None
EUT connector: Rear panel
Terminal block
Terminal block
Max. voltage: Front panel
240 Vac
N/A
Max. current: Front panel
16 Arms
N/A
Max. voltage: Rear panel
300 Vac
480 Vac
Max. current: Rear panel
40 Arms/Ph.
40 Arms/Ph.
(200 A Pk for 10 ms)
(200 A Pk for 10 ms)
Supply power: Voltage
115/230 Vac +/- 10%
115/230 Vac +/- 10%
Supply power: Current
<0.5 A
<0.7 A
Supply power: Frequency
50/60 Hz
50/60 Hz
Dimensions (H x W x D)
89 x 427 x 560 mm
89 x 427 x 560 mm
Weight
5 kg
5 kg
DAQ card and cable
Interface
PCI
PCI
Size
Standard height
Standard height
Resolution
16 bit
16 bit
Speed
250 kSamples/s
1.25 MSamples/s
Cable length PC to CCN
2 m
2 m
Technical information
HARMONICS AND FLICKER MEASURING SYSTEM
PROFLINE 2100 - OVERVIEW
INA 2151, 1-phase IEC 61000-3-3 16 Amp reference impedance
INA 2154, 3-phase IEC 61000-3-3 16 Amp per phase reference impedance
CCN 1000-1L, 1-phase coupling unit with integrated IEC 61000-3-3 16 Amp impedance
INA 2188, Rack mounting kit for CCN 1000-1, CCN 1000-1L or CCN 1000-3
WIN 2106, Test software for IEC 61000-3-11 and IEC 61000-3-12
Options
© February 2011 Teseq
®
Specifications subject to change without notice.
Teseq
®
is an ISO-registered company. Its products
are designed and manufactured under the strict
quality and environmental requirements of the ISO
9001. This document has been carefully checked.
However, Teseq
®
does not assume any liability for
errors or inaccuracies.
Teseq AG
Nordstrasse 11F 4542 Luterbach Switzerland
T + 41 32 681 40 40 F + 41 32 681 40 48
[email protected]
www.teseq.com
691-262A February 2011