Aes 5501 – Atec Teseq-AES_5501 User Manual
Page 3
Teseq AG
Nordstrasse 11F 4542 Luterbach Switzerland
T + 41 32 681 40 40 F + 41 32 681 40 48
[email protected]
www.teseq.com
AUTOMOTIVE EMISSIONS SYSTEM FOR ISO 7637-2
AES 5501
691-268B February 2011
Technical specifications
Complete system
1)
Battery current
100 A
Inrush current
2)
300 A for 200 ms
Battery voltage
0 to 60 VDC
Shunt resistor (R
S
)
10, 20, 40, 120 Ω, Ext.
Trigger modes
External, internal, manual
Battery off time (t
off
)
10 ms – 10 s ±(10% + 10 ms)
Battery on time (t
on
)
0.5 ms – 10.5 s ±(10% + 10 ms)
Mains input voltage
85 – 264 VAC, 47 – 63 Hz
Available relay voltage
12, 24, 36 V (for 42 V applications)
Electronic switch
Switching time Δt
S
300 ns ±20%
3)
Voltage drop
<1 V @ 25 A
Typical 2.1 V @ 100 A
Transient voltage protection
440 V
Mechanical switch
Type
Automotive relay
Contacts
High purity AgNi with no suppression across contacts
Voltage rating
> 400 V
Artifi cial network
Inductance
5 µH
Capacitance
0.1 µF
Resistance
50 Ω
Impedance
As per ISO 7637-2 (see above impedance curve)
Connectors
100 A MC type, countersunk, 50 mm above ground plane
Housing
Stainless steel, unpainted underside, screw terminal and
earth connections
Indicators
Counter on relay, LED indicator on controller for mechanical
and electronic switches
Measurements ports
MS 5501, ES 5501 - directly connected to output
AN 5501 – 5.6 k output impedance (to output connector –
necessary for improved RF performance)
Physical dimensions (L x W x H)
ES 5501
125 x 125 x 125 mm
MS 5501
125 x 125 x 125 mm
AN 5501
340 x 270 x 205 mm
All tolerances ± 10% unless otherwise noted.
© February 2011 Teseq
®
Specifications subject to change without notice.
Teseq
®
is an ISO-registered company. Its products
are designed and manufactured under the strict
quality and environmental requirements of the ISO
9001. This document has been carefully checked.
However, Teseq
®
does not assume any liability for
errors or inaccuracies.