15

Contact capacity:

250 VDC/0.1 A (resistive load),30 VDC/2 A (resistive
load),250 VAC/2 A (resistive load)

Remote Control Signal Input

Function:

Start and stop recording
Change chart speed
Start message printing
Start and stop memory sampling
Control statistical calculation interval

Input signal:

Non-voltage contact or open collector (TTL or
transistor)

Extension Modules
Unit to connect with:

DS400 or DS600 subunit (one for each subunit)

Number of input modules:

One input module can be mounted on an extension base
unit. Up to 3 extension base units can be connected to one
extension module in series.

Types of input modules:

10-ch universal input module
10-ch DCV/TC/DI input module

Extensible distance:

Up tp total length of 30 m

Communications Modules

Specifications Common to Communications Modules

Functions, Common Specifications

Outline of functions:

Output of measured values, output of set points,
setup of measurement conditions, control of start/
stop of measurement, etc.

Withstanding voltage:

1,500 VAC (50/60 Hz) for one minute between output
terminal and ground

GP-IB Modules
Electrical and mechanical specifications:Based on IEEE standard 488-1978
Addresses:

0 to 15

RS-232C Modules
Electrical and mechanical specifications: Based on EIA RS-232C
Communications format:

Half duplex

Synchronization:

Start-stop synchronization (synchronization by
means of the start and stop bits)

Baud rate:

150, 300, 600, 1200, 2400, 4800, 9600, 19200 or 38400
bps

Transmission distance:

Maximum of 15 m

Connector:

D-sub 25-pin connector

RS-422A/485 Modules
Electrical and mechanical specifications:

Based on EIA RS-422A and EIA RS-485

Connection method:

Multi-point

Address:

1 to 31

Communications format:

Half-duplex, 4-wire method/2-wire method

Synchronization:

Start-stop synchronization (synchronization by
means of start and stop bits)

Baud rate:

300, 600, 1200, 2400, 4800, 9600, 19200 or 38400 bps

Transmission distance:

Maximum of 1200 m

Connector:

6-screw terminal

Ethernel Modules
Network configuration:

Ethernet (10Base-T)

10Base-T modular connector:

1

Baud rate:

10 Mbps

Communication protocol:

TCP, UDP, IP, ARP or ICMP

Input data:

ASCII

Output data:

ASCII or binary

Model and Suffix Codes

DR230 Stand-alone model

DR231

Memory

Software

Input channel

Input

Power supply voltage

Power inlet, power cable

Additional specifications

Model

Suffix code

-0

-1

0

2

-1

-2

-3

1

2

3

4

D

F

R

S

/M1

/M3

/C1

/C2

/C3S

/C7

/N7

/N8

/A4

/R1

/H1

/H5

/D2

/P6

Description

Desk-top type hybrid recorder

No memory

3.5-inch FD

No DAQ 32 software

DAQ 32 software included

10 ch

20 ch

30 ch

Universal input, screw

Universal input, clamp

DCV/TC/DI input screw

DCV/TC/DI input clamp

100 to 240 VAC

3-pin power inlet w/UL CSA cable

3-pin power inlet w/VDE cable

3-pin power inlet w/SAA cable

3-pin power inlet w/BS cable

Computing functions

Report function

GP-IB

RS-232C

RS-422/485 (screw)

Ethernet

Power monitor for single phase

Power monitor for 3 phase

Alarm output module (A type 10 contacts)

2-point alarm output, remote control signal input, fail output, and chart end output

Internal illumination

Carrying handle

°

F display

DC power supply (AC and DC power supply coexist)

Must not coexist

Must not coexist

● The maximum allowable number for the / N , / C , / A4 and / R1 options is determined according

to the specified channel number.
10 ch: All options can be specified.
20 ch: All of them can be specified.
30 ch: 3 of them can be specified.

-1

DR230 Expandable model

DR232

Memory

Data conversion

Input

Power supply voltage

Power inlet, power cable

Additional specifications

Model

Suffix codes

-0

-1

0

2

Description

Desk-top type hybrid recorder

No memory

3.5-inch FD

No DAQ 32 software

DAQ 32 software included

Always -00

100 to 240 VAC

3-pin power inlet w/UL CSA cable

3-pin power inlet w/VDE cable

3-pin power inlet w/SAA cable

3-pin power inlet w/BS cable

Computing function

Report function

Internal illumination

°

F display

-1

D

F

R

S

/M1

/M3

/H1

/D2

Subunits and input/output modules must be ordered separately from the main unit.
The extersion cable must be ordered separately when the subunit is specified.

-00

Subunit: DS400, DS600

Model

Suffix codes

DS400

DS600

Type

Power supply voltage

Power inlet, power cable

-00

-1

D

F

R

S

W

Description

4-module connection type subunit

6-module connection type subunit

Always -00

100 to 240 VAC

3-pin power inlet w/UL CSA cable

3-pin power inlet w/VDE cable

3-pin power inlet w/SAA cable

3-pin power inlet w/BS cable

With 3-pin inlet screw conversion terminal

Configuration example of the expandable model

● 100 ch, 0.5 s universal input, with RS-232C and 20-ch alarm output
• DR230 expandable main-unit: DR232

×

1

• Sub unit: DS600

×

2

• Universal input module: DU100-11 or -12

×

10

• Communication module: DT300-21 (RS-232C)

×

1

• Alarm output module: DT200-21

×

2

• Extension cable

Ч

2