Atec Yokogawa-DR232 User Manual
Page 2
14
separately.) Refer to the power monitor module.
GP-IB Communications Option (/C1)
●
Applicable models and outline specifications
DR231 stand-alone model (For the DR232, the GP-IB module is sold separately.)
Refer to the GP-IB module.
RS-232C Communications Option (/C2)
●
Applicable models and outline specifications
DR231 stand-alone model (For the DR232, the RS-232C module is sold
separately.) Refer to the RS-232C module.
RS-422A/485 Communications Options (/C3S)
●
Applicable models and outline specifications
DR231 stand-alone model (For the DR232, the RS-422A/485 modules are sold
separately.) Refer to the RS-422A/485 module.
Ethernet Communications Option (/C7)
●
Applicable models and outline specifications
DR231 stand-alone model (For the DR232, the Ethernet module is sold
separately.) Refer to the Ethernet module.
Alarm Contact Output Option (/A4)
●
Applicable models and outline specifications
DR231 stand-alone model (For the DR232, the alarm contact output module is
sold separately.) Refer to the alarm output module.
Recorder Function Remote Control Option (/R1)
●
Applicable models and outline specifications
DR231 stand-alone model (For the DR232, the DI/DO module is sold separately.)
The DR232 expandable model incorporates fail and chart-end outputs as
standard features. Refer to the DI/DO module.
Input Module
Specifications Common to Input Module
●
Normal Operating Temperature/Humidity Range
Universal, DCV/TC/DI input modules:
–10 to 60˚C, 20 to 80% RH
(non condensing)
mA, power monitor, strain, pulse input modules: 0 to 50˚C, 20 to 80% RH
(non condensing)
●
Withstanding Voltage
Between input terminals:
1,000 VAC (50/60 Hz) for one minute
Strain input: 50 VDC (50/60 Hz, 1
minute, except DU500-14)
Between input terminal and ground:
1,500 VAC (50/60 Hz) for one minute
Universal Input Modules
DCV/TC/DI Input Modules
Model
Module
Number of Channels Type of Terminal Measurement Interval
Universal input
DCV/TC/DI input
DU100-11
DU100-12
DU100-21
DU100-22
DU100-31
DU100-32
DU200-11
DU200-12
DU200-21
DU200-22
DU200-31
DU200-32
10
10
20
20
30
30
10
10
20
20
30
30
Screw
Clamp
Screw
Clamp
Screw
Clamp
Screw
Clamp
Screw
Clamp
Screw
Clamp
0.5 s
0.5 s
2 s
2 s
2 s
2 s
0.5 s
0.5 s
2 s
2 s
2 s
2 s
●
General Specifications
Input method:
Floating imbalance input, and inter-channel isolation
RTD and pulse inputs are of the same potential within
the same input module.
A/D resolution:
±
20,000
A/D integration time:
Manual selection or automatic switchover between
20 ms (50 Hz), 16.7 ms (60 Hz) and 100 ms (10 Hz)
Measurement Range
DC voltage range:
20 mV to 50 V
Thermocouple:
R, S, B, K, E, J, T, L, U, N, W, KP-Au7Fe
RTD:
Pt100, JPt100, Ni100, Ni120, Cu10, and J263*B
Contact input:
Voltage-free contact input or voltage input
Mixed input is allowed for DC voltage, thermocouple, RTD and contact inputs.
(For an DCV/TC/DI input module, RTD input is not allowed.)
Measurement accuracy:
±
(0.05% of reading + 2 digits)
(at 2-V range, 23
±
2˚C and 55
±
10% RH)
Noise rejection:
By means of integrating A/D, low-pass filter or moving
average
Burnout:
Detected within thermocouple-input range
DC Current Input Modules
Model
DU300-11
DU300-12
Number of Channels
10
10
Measuring Interval
0.5 s
0.5 s
Type of Terminals
Screw
Clamp
●
General Specifications
Input method:
Floating imbalance input, and inter-channel isolation
Shunt resistor (100
Ω
) is pre-installed.
A/D resolution:
±
20,000
A/D integration time:
Manual selection or automatic switchover between
20 ms (50 Hz), 16.7 ms (60 Hz) and 100 ms (10 Hz)
Measurement range (resolution):
±
20 mA (1
µ
A)
Noise rejection:
By means of integrating A/D, low-pass filter or moving
average
Power Monitor Modules
Model
Number of Channels
Type of Terminal Measurement Interval
DU400-12 For single phase: one for voltage and one for current
Clamp
2 s
DU400-22 For 3 phases: three for voltage and three for current
Clamp
2 s
Input method:
Transformer isolation
Measured variables:
Six items can be selected from the following: RMS
value of AC voltage/current, active power, apparent
power, reactive power, frequency, power factor and
phase angle (There is a restriction in combining
selected items.
Measurement range (resolution):
Voltage:
250 V (0.1 Vrms), 25 V (0.01 Vrms)
Current:
5 A (0.001 Arms), 0.5 A (0.001 Arms)
Measurement accuracy:
±
(0.5% of span when RMS V and A are measured)
Measured frequency:
45 to 65 Hz (all channels must have the same frequency)
Crest factor:
Up to 3
Power integration:
Calculated by /M1 (computation functions) option.
/M1 must be specified for the DR230.
Strain Measurement Modules
Model
Number of Channels
Type of Terminal Measurement Interval
DU500-12
10*, with built-in 120
Ω
resistance
Clamp
0.5 s
DU500-13
DU500-14
10*, with built-in 350
Ω
resistance
10*, for external bridge box
Clamp
NDIS
0.5 s
0.5 s
*: 2 modules' width is required.
●
General Specifications
Measurement range (resolution):
2,000
µε
(0.1
µε
) ,20,000
µε
(1
µε
) ,200,000
µε
(10
µε
)
Built-in bridge resistance:
120
Ω
, 350
Ω
, or none (for an external bridge box)
Wiring:
1/4 bridge, 1/2 bridge (neighbor), 1/2 bridge (opposite),
full bridge
Applicable gaugeresistance: 1/4 or 1/2 bridge: 120 or 350
Ω
Full bridge:
100 to 1,000
Ω
Bridge voltage:
Fixed at 2 V
Gauge factor:
2.00 (with scaling function)
Strain balance:
Electronic auto-balancing (can be turned on or off in
each module) within
±
10,000
µε (1/4
bridge
)
Pulse Measurement Modules
Model
Number of Channels
Type of Terminal Measurement Interval
DU600-11
10
Screw
0.5 s*
*: Rate of data update is fixed at one-second interval.
Input method:
Shared common line within the same module
Type of input:
Non-voltage contact or open collector (TTL or
transistor)
Measurement modes
RATE (count value instantaneous mode):
The number of pulses input during the most recent
one-second period of measurement is output as the
scale set value.
GATE (ON time instantaneous mode):
The ON (make)/OFF (break) state (ON = 1, OFF = 0)
of the contact input during the most recent one-
second period of measurement is output as the scale
set value.
Pulse integration:
The computation function is used when integrating
either the count value each second or the ON period.
Computation formula:
TLOG.PSUM (XXX)
Number of computation channels:
Max. 60 channels
Max. count value/ON period:
99999999
(/M1 (computation option) need not be specified for
the DA100 or DR recorder main unit. Pulse integration
can be used automatically when a pulse module is
recognized.)
Maximum input frequency:
6 kP/s (10 P/s for voltage-free contact)
Filter:
For rejection of chattering up to 5 ms (can be turned
on and off for every channel)
Digital Input Module
Model
Number of Channels
Type of Terminal Measurement Interval
DU700-11
10
Screw
0.5 s
●
General Specifications
Input method:
Unbalanced floating-point, with channel-to-channel
isolation (individually separated channels)
Measuring range:
Voltage input
2.3 V or less ............. 0
2.5 V or greater ........ 1
Voltage-free contact input
Off (open) ................. 0
On (closed) .............. 1
Maximum input voltage range:
Voltage input
±
60 V DC
Voltage-free contact input
±
10 V DC
Alarm, DI/DO and Other Modules
Alarm Contact Output Modules
Model
Number of Outputs
Contact Arrangement
Type of Terminal
DT200-11
DT200-21
4
10
SPDT (NO-C-NC)
Make contact (NO-C)
Screw
Screw
●
General Specifications
Output mode:
Selection between excitation and non-excitation,
output hold and non-hold and AND and OR modes
Re-breakdown re-alarm: Maximum of 6 contacts can
be selected.
Contact capacity:
250 VDC/0.1 A (resistive load),30 VDC/2 A (resistive
load),250 VAC/2 A (resistive load)
DI/DO Modules
●
Common Specifications
Model:
DT100-11
The DR232 expandable model incorporates fail and chart-end output as standard
features. (Up to 1 module can be connected to the DR230 expandable model.)
●
Alarm Contact Output
Number of outputs:
2
Contact mode:
C contact—NO-C-NC terminal
Contact capacity:
250 VDC/0.1 A (resistive load),30 VDC/2 A (resistive
load),250 VAC/2 A (resistive load)
●
Chart End Output
Outline of functions:
The chart end output terminal is energized if the
recording paper in the recorder breaks.
The DR stand-alone model uses the /R1 option.
Contact mode:
Make contact (NO-C). Cannot be switched between
excited and non-excited.
Contact capacity:
250 VDC/0.1 A (resistive load),30 VDC/2 A (resistive
load),250 VAC/2 A (resistive load)
●
Fail Output
Function:
If an abnormality is found in the total system, the fail
output terminal is de-energized.
Output mode:
Make contact (NO-C). Cannot be switched between
excited and non-excited.