Technical specifications – Atec TTC-2209 User Manual
Page 8
8
Technical Specifications
Physical Characteristics
Overall Dimensions:
7.5 x 11.5 x 2.25 in. (19 x 29.2 x 5.7 cm)
Weight:
4.25 lb. (1.93 kg), with battery
Environment
Temperature Range
Operating:
32
°
F to 122
°
F (0
°
C to 50
°
C)
Storage:
-40
°
F to 167
°
F (-40
°
C to 75
°
C)
Humidity:
10% to 90% relative humidity,
non-condensing
Power Requirements
AC Adapter:
100-220 at 60 Hz or
200-240 at 50 Hz VAC
to 19 VDC, 2.37 AMPS
Charging Time:
Maximum of 2 hours from full
discharge
Battery Type:
10.8 V NiMH
Operating Time:
Typically 3 hours on a full charge (DS1
operation only)
Typically 2 hours on a full charge (DS3
operation only)
Display
6-inch diagonal graphic LCD
color display
Input and Output Connectors
Bantam (4) and RS-232 (printer
operation)
Input Impedance
BRIDGE:
≥
1000
Ω
TERM:
100
Ω
_
±
5%
DSX-MON:
100
Ω
_
±
5%
Receive Level
BRIDGE or TERM:
+6 to -35 dBdsx
DSX-MON:
+6 to -24 dBdsx (of resistive loss)
Line Build Out (LBO)
Range:
0, -7.5, -15.0, -22.5 dB
Accuracy:
±
1 dB at 772 kHz
Transmit Timing Sources
Internal Clock, Recovered Clock
Line Codes
AMI, B8ZS
DS3 Options
Input and Output Connectors
WECO 560A
Impedance
75
Ω
, nominal unbalanced to ground