Applications, Ds1 physical layer testing – Atec TTC-2209 User Manual
Page 3
3
DSX-1
SWITCH
NIU/
SMART
JACK
NIU/
SMART
JACK
CSU/
DSU
NETWORK
T1
T1
T1
T1
2209
2209
Simultaneously monitor and test
in both directions on a circuit
Applications
The 2209 is designed to simplify testing of today’s complex networks. Programmed with highly integrated applications
for in-service and out-of-service testing, the 2209 tests at both the pipeline and service levels to ensure that your network
is performing as advertised. Applications include:
DS1 Physical Layer Testing
Whether provisioning or troubleshooting T1 service, the first step is to verify proper circuit operation throughout the
network by testing the physical layer. Typical requirements include BER testing, signal, alarm, and timing tests to
ensure proper performance of T1 network connections.
BER testing is typically conducted from the customer premises at an NIU or HTU-R. To identify and sectionalize
circuit problems from network equipment faults, the 2209 provides the capability to monitor and perform BER testing
in both directions of a circuit simultaneously. The use of standard or user-programmable loopcodes to loop-back
network equipment allows for further sectionalization of network troubles. In addition to commonly used BER
patterns such as QRSS, the 2209 also offers several industry-recommended advanced stress patterns, including 55 Octet
and T1 Daly to ensure network performance.
Advanced timing analysis allows the technician to pinpoint signal delays, timing slips, and mismatches between switch
and remote equipment.