beautypg.com

375 field communicator, Specifications, Product data sheet – Atec Fisher-Rosemount-HART-375 User Manual

Page 5

background image

As for reliable, when was the last

time you had to send your 275

HART Communicator in for repair?

That’s exactly the kind of reliability

we’ve built into the 375. The 375

Field Communicator is designed,

manufactured and tested to

specifications that are even

more demanding. The 375

Field Communicator is designed

to go wherever you have to go

to get the job done.

Even the battery pack is approved

for installation in hazardous areas.

The 375 Field Communicator is

designed for use in areas where

laptops shouldn’t go.

Rugged and Reliable.

It’s called ‘Field Communicator’ for

a reason. Some tasks just have to

be performed at the device. The

375 Field Communicator is designed

for tough use in your plant or mill.

Its large keys and physical

navigation buttons allow for one-

handed operation, even with your

work gloves on. The rugged display

is designed to take the knocks and

shocks from normal use in the plant.

Intrinsically Safe.

The 375 Field Communicator meets

the Intrinsic Safety requirements

of the listed regulatory agencies

and standards. All of the available

Hazardous Locations approvals

are provided in a single model

option (see Ordering Information).

– CENELEC/ATEX

– Factory Mutual (FM)

– Canadian Standards Association (CSA)

– FISCO

Page 5

Specifications

Processor and Memory
Specifications

Microprocessor

80 MHz Hitachi

®

SH3

Memory Internal Flash

32 MB

System Card

128 MB or higher secure digital card

RAM

32 MB

Expansion Module

32 MB or higher secure digital card

PHYSICAL Specifications

Weight

Approximately 2 lb. (0.9kg) with battery

Display

1/4 VGA (240 by 320 pixels)
monochrome 3.8” (9.6 cm) transflective
display with touch screen

Anti-glare coated

Keypad

25 keys including 4 action keys,
12 alphanumeric keys, 4 programmable
function keys, on/off, and 4 cursor-control
(arrow) keys; membrane design with
tactile feedback

ENVIRONMENTAL Specifications

Usage

-10° C (14° F ) to +50° C (122° F )

0% to 95% RH (non-condensing)
for 0° C (32° F ) to +50° C (122° F )

Charge

0° C (32° F ) to +40° C (104° F )

Storage

-20° C (-4° F ) to +55° C (131° F )
with batteries

Storage Without Batteries

-20° C (-4° F ) to +60° C (140° F )

Enclosure Rating

IP51 (from front)

Shock

Tested to survive a 1-meter
drop test onto concrete

EASY UPGRADE REQUIREMENTS

Usage

PC with internet access

CD Rom drive

IrDA port (or adapter)

Windows 2000 or XP

POWER SUPPLY Specifications

Battery Pack

Rechargeable NiMH batteries

Battery Operating Time

Up to ten hours depending on usage

Battery Charger Options

Input voltage 85-240 VAC, 50/60 Hz

Cables included with U.S., European
and U.K. plugs

ONNECTION

CONNECTION Specifications

Battery Charger

Mini DIN 4-pin jack

HART and Fieldbus

Three 4mm banana plugs (one common
to HART and Foundation fieldbus)

IrDA Port

IrDA (Infrared Data Access) port
supporting up to 115 Kbps

± 15 degrees recommended maximum
angle from center line

Approximately 12” (30 cm)
recommended maximum distance

Product Data Sheet

December 2003

375 Field Communicator