General Specifications

FLUKE-741B Documenting Process Calibrator
FLUKE-743B Documenting Process Calibrator
FLUKE-744 Documenting Process Calibrator-HART
Included with the Fluke 740 Series:
Type TL224 Industrial Test Leads (two sets), AC220
Test Clips (2 sets), TP220 Test Probes (1 set), Battery
Pack, Battery Charger, serial port cable (except 741B),
HART communications cable (744 only), DPC/TRACK
Sample with free PC communication utility software
(except 741B), Instruction Manual, NIST-traceable
calibration report and data, three-year warranty.

FLUKE-700SW DPC/TRACK Software (for use with
Model 743B or 744 calibrators)
Included with DPC/TRACK software:
Software media, Instruction Manual, Serial Port Cable,
DB9 to DB25 (9 pin to 25 pin) Adapter.

FLUKE-700 Pxx Pressure Modules
Included with each Fluke Pressure Module:
BP-ISO Adapter(s) (except with P29 - P31), Instruction
Sheet, NIST traceable calibration report and data,
one-year warranty.

FLUKE-744 Upgrade
Fluke-744V20

HART Upgrade Revision 2.5

Accessories
Fluke-700PMP

Pressure Pump; 100 psi/7 bar

Fluke-700LTP

Low Pressure Test Pump

Fluke-700PTP

Pneumatic Test Pump; 360 psi/25 bar

Fluke-700HTP

Hydraulic Test Pump; 10,000 psi/
700 bar

Fluke-700HTH

Hydraulic Test Hose

Fluke-700PRV

Pressure Relief Valve Kit for HTP

Fluke-700-IV

Current Shunt (for mA/mA
applications)

Fluke-700PCK

Pressure Calibration Kit

Fluke-700BCW

Bar Code Wand

Fluke-700TC1

TC Mini-Plug Kit, 9 types

Fluke-700TC2

TC Mini-Plug Kit, JKTERS

80T-IR

Infrared Probe

80PK-IR

Infrared Probe

BE9005

Battery Eliminator

BC7217

Battery Charger

BP7217

NiCd Battery Pack

BP7235

NiMH Battery Pack

C700

Hard Carrying Case

C781

Soft Carrying Case

C789

Soft Carrying Case

C75

Test Lead Case

Ordering Information

Fluke. Keeping your world

up and running.

Fluke Corporation
PO Box 9090, Everett, WA USA 98206

Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands

For more information call:
U.S.A. (800) 443-5853 or Fax (425) 446-5116
Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222
Canada (800) 36-FLUKE or Fax (905) 890-6866
Other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116
Web access: www.fluke.com

©2004 Fluke Corporation. All rights reserved.
Printed in U.S.A. 9/2004 1263323 A-US-N Rev H

Data log function (except 741B)
Measure functions:
Voltage, current, resistance,
frequency, temperature, pressure
Reading rate: 1, 2, 5, 10, 20, 30, or 60 readings per
minute
Maximum record length: 8000 readings
(7980 for 30 or 60 readings per minute)

Ramp function
Source functions:
Voltage, current, resistance,
frequency, temperature
Rate: 4 steps/second
Trip detect: Continuity* or voltage

*Continuity detection not available when sourcing current

Loop power function
Voltage:
Selectable, 24 V or 28 V
Accuracy: 5%
Maximum current: 22 mA, short-circuit protected
Maximum input voltage: 30 V dc

Note: 250

series resistance is automatically supplied whenever loop power is

enabled on 744.

HART modem interface (744 only)
Maximum input voltage: 30 V dc

Environmental specifications
All calibrator specifications apply from +18 °C to
+28 °C unless stated otherwise.
Operating temperature: -10 °C to 50 °C, (-20 °C typical
except for frequency and ac voltage measurement)
Storage temperature: -20 °C to 60 °C
Operating altitude: 2800 m above mean sea level
(9186 ft)
90-day specifications: The standard specification
intervals for the 740 Series are 1 and 2 years. Typical
90-day measurement and source accuracy can be
estimated by dividing the one year “% of reading” or
“% of output” specifications by 2. Floor specifications,
expressed as “% of f.s.” or “counts” or “ohms” remain
constant.

Power: Internal battery pack NiCd, 7.2 V, 1700 mAh;
NiMH (744 only) 7.2 V, 3500 mAh
Battery Life: Typical usage, >8 hours
Dimensions: 130 x 236 x 61 mm (5.1 x 9.3 x 2.4 in.)
Weight: 1.4 kg (3 lbs. 1 oz.)
Side Port Connections:

Pressure module connector

RS-232 connector (743B and 744) to interface to
your PC

Connection for optional battery eliminator

Safety: Complies with CAN/CSA C22.2 No 1010.1-92,
ANSI/ISA S82.01-1994, UL3111, and EN610-1:1993.
Data Storage Capacity:
Fluke 741B—1 day of calibration results
Fluke 743B and 744—1 week of calibration results

11