Atec Fluke-5502A User Manual
Page 3
![background image](/manuals/319610/3/background.png)
Practical solutions
for calibrating in
the lab or in the field
Fluke Calibrators
Multi-Product
Calibrators
Multifunction
Calibrators
Workload
5080A
5502A
5522A
5700A
5720A
Analog/Panel meters
High burden meters
Low burden meters
DMMs
Basic dc V accuracy
100 ppm
50 ppm
11 ppm
6.4 ppm
3.25 ppm
3.5 digits
(typ. ± 0.3 % dc V)
4.5 digits
(typ. ± 0.025 % dc V)
5.5 digits
(typ. ± 0.015 % dc V)
6.5 digits
(typ. ± 0.0024 % dc V)
7.5 digits
(typ. ± 12 ppm dc V)
8.5 digits
(typ. ± 3.9 ppm dc V)
Temperature/Pressure
RTD simulate
RTD measure
Thermocouple simulate
Thermocouple measure
Pressure modules
opt
Oscilloscopes
1 channel
200 MHz to 600 MHz
200 MHz
opt
300 MHz or
600 MHz
opt
600 MHz
opt
1.1 GHz
opt
2.1 GHz
3.2 GHz
6 GHz
25 ps fast edge
Safety testers
Hipot
Megohm meters
opt
Installation
PATs
Continuity
opt
Power/Energy
Wattmeters
Harmonic analyzers
Flicker meters
PQ opt
Phase angle meters
PQ opt
Power analyzers
PQ opt
Power recorders
Other
Clamp meters
LCR meters
CR only
CR only
Process calibrators
Data acquisition
Non sine waveforms
RF millivolt meters
opt
opt
# of calibrator functions
8
11
11
5
5
3 5502A Multi-Product Calibrator
A full-functioned calibrator
that covers a wide range of
common workload
The 5502A Multi-Product Calibrator addresses
common workload items like 3.5 and 4.5 digit
digital multimeters and more. It comes with
internal and external protection features that
enable you to transport it easily and perform
on-site or mobile calibration. The 5502A can
also be fully automated with MET/CAL
®
Plus
Calibration Management Software. It is the ideal
calibrator for metrology professionals who need a
solution for calibrating low-to-medium accuracy
electrical instrumentation.
The 5502A sources direct voltage and current;
alternating voltage and current with multiple
waveforms and harmonics; simultaneous volt-
age and current outputs or dual voltage outputs to
simulate dc and ac power with phase control; as
well as resistance, capacitance, thermocouples and
RTDs. The 5502A can also measure thermocouples
and thermocouple simulators. Two options add
the capability to calibrate oscilloscopes to either
300 MHz or 600 MHz.
Using the Fluke Calibration 52120A
Transconductance Amplifier, the 5502A’s output
current can be extended from 20.5 to 120 A;
and with the use of 25 and 50 turn coils, it can
calibrate instruments requiring up to 6000 A.
The 5502A calibrator covers many
of the most common items in your
workload, including:
•
Handheld and bench meters
(analog and digital) to 4.5 digits
•
Current clamps and clamp meters
•
Panel meters
•
Electronic thermometers
•
Chart recorders
•
Oscilloscope recorders
•
XY recorders
•
Data loggers