beautypg.com

2400 series technical specifications – Atec Giga-tronics-2420L-2420M User Manual

Page 2

background image

Minimum Settable:

-20 dBm; -10 dBm, >20 GHz

(Option 26)

-110 dBm ; -100 dBm, >20 GHz

Power Offset:

0 to 10 dB

Resolution

0.05 dB

Temperature Stability:

0.025 dB/ºC

Output Source Match (typical):

< 2.0:1

Accuracy (dB)

(Specifications apply over 15 to 35ºC range and degrades <0.5

dB outside the range)

.01 - 20 GHz

20 - 40 GHz

± 1.0
± 1.2

± 0.8
± 1.0

± 1.3
± 1.5

Model

> 5 dBm

> -20 dBm

> -110 dBm

20 GHz

26.5 GHz

40 GHz

+ 16
+ 13
+ 10

+ 15

+ 9
+ 9

+10

+9

Model

.01 - 8 GHz

8 - 20 GHz

20-40 GHz

2

Frequency

Accuracy:

Same as time-base

Resolution:

0.1 Hz

Power Slope:

0 to 0.5 dB/GHz

Internal Reference:

100 MHz

Aging Rate:

< 1 X 10

-8

/day

Temperature Stability:

< ± 2 X 10

-8

/ºC

10 MHz Reference Output:

TTL level into 50 Ω

External Reference Input:

10 MHz or 100 MHz ± 1ppm

> - 5 dBm into 50 Ω

High Stability Time Base

10 MHz

(Option 28)

Aging Rate

< 5 X 10

-10

/day

Temperature Stability

< ± 5 X 10

-10

/ºC

Volts/GHz:

0 to 10 V range: 0.50 V/GHz, 0.01 – 20 GHz

0.25 V/GHz, 20 – 40 GHz

Lock/Level Indicator:

Sync Out = TTL High

Frequency Bands

2400 Series

Technical Specifications

All specifications apply over a 0˚C to +55˚C range after 30 minutes of warm-up time unless otherwise stated.

2400L Series Typical Maximum Output Power

0.00

5.00

10.00

15.00

20.00

25.00

30.00

0

5000

10000

15000

20000

25000

30000

35000

40000

P

ow

er

(d

B

m

)

2440L

Frequency (MHz)

2420L

-1

-0.8

-0.6

-0.4

-0.2

0

0.2

0.4

0.6

0.8

1

Frequency (MHz)

O

u

tp

u

t

Le

ve

l E

rr

o

r

(d

B

)

2440L Series Output Level Error Accuracy (Option 26)

0

4000 8000 12000 16000 20000 24000 28000 32000 36000 40000

-40 dBm

+5 dBm

-15 dBm

Output Power

Maximum Leveled (dBm)

1

(Specification applies over 0 to 35ºC range and

degrades <2.0 dB from 35ºC to 55ºC)

Output Power and Level Accuracy for the 2400 Series

Spectral Purity

Harmonics

(Specifications for harmonics above instrument frequency range are

typical.)

Sub-Harmoncs

Spurious

(Specification is -45 dBc typical for offsets < 300 Hz)

1 Step Attenuator (Option 26) reduces power by 1.5 dB to 18 GHz, 2.0 dB

18- 26.5 GHz, and 2.5 dB above 26.5 GHz.

2 20 - 26.5 GHz for model 2426

3 .01- 2 GHz range- (-30 dBc below 100 MHz)

Frequency

(GHz)

Standard

(at +6 dBm)

.01 – 2 GHz

3

2 – 20 GHz

20 – 40 GHz

– 50 dBc
– 55 dBc
– 30 dBc

Frequency

(GHz)

Standard

(at +6 dBm)

.01 – 2 GHz
2 – 20 GHz

20 – 40 GHz

– 80 dBc
– 60 dBc
– 50 dBc

Frequency

(GHz)

Offsets

> 300 Hz

.01 – 16 GHz
16 – 32 GHz
32 – 40 GHz

– 60 dBc
– 54 dBc
– 48 dBc

0
1
2
3
4
5
6
7
8
9

10
11
12

10 – 15.99 MHz
16 – 30.99 MHz
31 – 62.99 MHz

63 – 124.99 MHz

125 – 249.99 MHz
250 – 499.99 MHz
500 – 999.99 MHz

1.0 – 1.99 GHz
2.0 – 3.99 GHz
4.0 – 7.99 GHz

8.0 – 15.99 GHz

16.0 – 31.99 GHz
32.0 – 40.00 GHz

512
256
128

64
32
16

8
4
2
1

1/2
1/4
1/8

Band

Frequency

N

2