12
Signal Generation
201
Contents Overview
R&S Addresses
Type Index
Chapter Overview
Contents Overview
R&S Addresses
Type Index
Chapter Overview
Specifications in brief
Frequency
Range
SME02/03
5 kHz to 1.5/3 GHz
SME03E/06
5 KHz to 2.2/6 GHz
Resolution
0.1 Hz
Setting time
after IEC/IEEE-bus delimiter
<10 ms
after trigger pulse in list mode
<500
µ
s
Phase offset
adjustable in steps of 1
°
Reference frequency
standard
option SM-B1
Aging (after 30 days of operation
1 x 10
−
6
/year
<1 x10
−
9
/day
Temperature effect (0 to 55
°
C) 2
x
10
−
6
<5 x10
−
8
Spectral purity
Spurious signals
Harmonics <
−
30 dBc, <
−
26 dBc with SM-B3/-B8/-B9
Nonharmonics at
>5 kHz from carrier, f <1.5 GHz
<
−
80 dBc
SSB phase noise at 20 kHz from carrier, 1 Hz bandwidth,
FM/
ϕ
M deviation <5% of max. deviation
<93.75 125
250 MHz 0.5
1
2
3
6 GHz
<
−
129 <
−
140 <
−
137
<
−
132 <
−
126 <
−
120 <
−
116 <
−
116 dBc
Residual FM, rms (f=1 GHz)
0.3 to 3 kHz (CCITT)
<1 Hz
0.03 to 20 kHz
<4 Hz
Level
−
144 to +13 dBm
Resolution
0.1 dB
Accuracy for levels >
−
127dBm
f <1.5 GHz
±
1 dB
f >1.5 GHz
±
1.5 dB
f >3 GHz
±
2 dB
Level frequency response at 0 dBm
1 dB, typ. 0.3 dB
Overload protection
protects the unit from externally
applied RF power (50
Ω
source) and
DC voltage, SME02 and 03:
≤
50 W/
35 V; SME06:
≤
1 W/0 V
Simultaneous modulation
any combination of AM, FM (
ϕ
M),
pulse modulation and DM (DM = FSK,
4FSK, FFSK, GFSK, GMSK or
QPSK)
Frequency modulation
with option SM-B5
Operating modes
internal, external AC/DC, two-tone
with two separate channels FM1 and
FM2
Maximum deviation
depending on carrier frequency:
500 kHz (
<
130 MHz) to 4 MHz
(6 GHz)
Setting error at AF=1 kHz
<3% of reading + 20 Hz
FM distortion at AF=1 kHz
and 50% of max. deviation
<0.5%, typ. 0.05%
Modulation frequency range
for maximum deviation
DC to 500 kHz
for <25% of max. deviation
DC to 2 MHz
Carrier frequency offset with FM
depending on carrier frequency:
<50 Hz (f
c
<
93.75 MHz) to
<100/200 Hz (f
c
1.5/3 GHz)
+1% of deviation
Phase modulation
with option SM-B5
Operating modes
internal, external AC/DC, two-tone
with two separate channels
ϕ
M1 and
ϕ
M2
Maximum deviation
depending on carrier frequency:
5 rad (f
c
<130 MHz) to 40 rad
(f
c
6 GHz)
Setting error at AF=1 kHz
<3% of reading + 0.01 rad
Distortion at AF=1 kHz and
50% of max. deviation
<1%
Modulation frequency range
DC to 100 kHz
Digital modulation
with option SME-B11,
standard in SME03E
Modulation modes
FSK, 4FSK, FFSK, GFSK, GMSK,
QPSK,
π
/4 DQPSK
Operating modes
internal, external
Internal data generator
programming of data, level switching
and burst output
Storage capacity
3
x 8192 bit
Frequency accuracy
same as reference frequency
PRBS (pseudo-random bit sequence) selectable lengths: 2
9
−
1, 2
15
−
1,
2
20
−
1, 2
21
−
1 or 2
23
−
1
FSK
to Cityruf, POCSAG, FLEX specs
Shift, filtered
4/4.5/4.8 kHz
unfiltered
0.01 to 400 kHz, maximum shift
depending on carrier frequency
Data rate, filtered
0.05 to 90 kbit/s
unfiltered
0.05 to 1900 kbit/s
FFSK
to Cityruf, POCSAG specifications
Shift
1.5/2/3/3.5/4/4.5 kHz
Data rate
0.05 to 90 kbit/s
4FSK
to APCO25, ERMES, FLEX,
MODACOM specifications
Shift
0.01 to 400 kHz, maximum shift
depending on carrier frequency
Data rate
1 to 24.3/27 to 48.6 kbit/s
GFSK
to CT2, CT3, DECT specifications
Shift
18/160/288 kHz as well as non-
standard shifts
Data rate
10 to 585/640 to 1170 kbit/s
GMSK
to CDPD, GSM1800, DSRR, GSM,
MC9, MD24 to MD192,
MOBITEX8000 specifications
Data rate
2.4/3.6/4/4.8/6/8/9.6/10/12/
16/19.2/270.833/1000 kbit/s
QPSK
, π
/4 DQPSK
to APCO25, MSAT, NADC, PDC,
TETRA, TFTS specifications
for f >3 GHz
not specified
Data rate
1 to 24.3/27 to 48.6 kbit/s
Filter
√
cos0.35/0.4/0.5/0.6
cos0.2/0.35/0.4/0.5/0.6
Amplitude modulation, pulse modulation, internal modulation generator, LF gen-
erator, multifunction generator, stereo multiplex signal, VOR modulation signal,
ILS modulation signal, pulse generator and sweep see SMT, page 198
List mode
automatic, single-shot, manual,
(not SME03E)
externally triggered
Max. number of channels
2000
Step time
1 ms to 1 s
Remote control
IEC 625 (IEEE 488)
Command set
SCPI 1992.0
General data
Power supply
90 to 132/180 to 265 V,
47 to 440 Hz, autosetting to AC volt-
age, max. 300 VA
Dimensions (W x H x D)
435 mm x 192 mm x 460 mm
Weight
25 kg for fully equipped unit
Ordering information
Signal Generator SME02
1038.6002.02
SME03
1038.6002.03
SME03E
1038.6002.13
SME06
1038.6002.06
Options
Reference Oscillator OCXO
SM-B1
1036.7599.02
LF Generator
SM-B2
1036.7947.02
Pulse Modulator for SME02
SM-B3
1036.6340.02
Pulse Modulator
for SME03
SM-B8
1036.6805.02
Pulse Modulator
for SME06
SM-B9
1039.5100.02
Pulse Generator (only in combination
with SM-B3, SM-B8 or SM-B9)
SM-B4
1036.9310.02
FM/
ϕ
M Modulator
SM-B5
1036.8489.02
Multifunction Generator
SM-B6
1036.7760.02
DM Coder
SME-B11
1036.8720.02
DM Memory Extension (8 Mbit)
SME-B12
1039.4090.02
FLEX Protocol
SME-B41
1039.5645.02
POCSAG Protocol
SME-B42
1039.5745.02
Rear Connectors
for RF and LF
SME-B19
1039.3907.02