0°c to +40°c, 0°c to +70°c, 95%, non-condensing – Atec MCL-MT4100 Series User Manual

Page 3: 10 g, 11ms, Closed loop circuit

background image

INC

INC

A

MITEQ

COMPANY

C O N T R O L A N D S TAT U S C A PA B I L I T I E S

TYPE

FUNCTION

Filament ON/OFF

Units Select

Fault Counter ON/OFF

Transmit/Standby

*Hold Power ON/OFF

Antenna Position (1:1)

Controls

*RF ON/OFF

Auto Switching (1:1)

Load Position (1:1)

Reset

Manual Switching (1:1)

Local/Remote/Computer

*Attenuation

*Auto Power

RF Reflected Power Alarm

RF Reflected Power Fault

Tube Temperature Alarm

RF High Alarm

Filament Under Current Fault

Adjustable Parameters

RF Low Alarm

Comm Band Rate

Comm Protocol

Comm Address

Time

Date

RF Forward Power

Helix Current

RF Reflected Power

Displays

Helix Voltage

Tube Temperature

Filament Current

Filament Delay

PS Temperature

Tube Temperature Switch

WG Pressure

PS Temperature

Faults

Tube Temperature Analog

Helix Surge Current

Chassis Interlock

(Notification,

Helix Run Current

HV Over Voltage

Filament Under Current

RF & HV Shutdown)

HV Under Voltage

User Interlock

RF High

RF Low

PS Temperature

Alarms

RF Reflected

Tube Temperature

RF Switch Failed

(Notification Only)

Blower Failed

AC Low Line

Exciter

Delay

Transmit Selected

Sampler Port Cal Table

Summary Alarm

Summary Fault

RF Low Switching ON/OFF

Additional Status

Computer Tx

Computer Rx

Remote Tx

Remote Rx

Event Log

Fault Log

Maintenance Log

* Optional

ENVIRONMENTAL
SPECIFICATIONS

Operating Temperature:

-1

0°C to +40°C

Non-Operating Temperature:

-4

0°C to +70°C

Relative Humidity:

95%, non-condensing

Operating Altitude:

10,000 ft. above sea level (3,048 m)
with standard adiabatic derating

Non-Operating Altitude:

50,000 ft. above sea level (15,240 m)

Vibration:

Method 514-4 of
MIL-STD-810E Procedure I, Figures 514.4-1,
514.4-2, 514.4-3

Shock:

10 g, 11ms

MECHANICAL
SPECIFICATIONS

RF Connectors:

Input:

Type SMA female

Output: 2.0–8.0

GHz SC (Male)

6.0 – 18.0

WRD-650

7.5 – 18.0

WRD-750

Installed Weight:

Figure 2: 65 lbs.
Figure 1: 90 lbs.

Cooling:

Closed Loop Circuit