beautypg.com

Signal recovery, Why should you choose, Products – Atec Signal-Recovery-7280 User Manual

Page 4

background image

CatIss7Web:0710UK

www.signalrecovery.com

They are the only commercially available 2 MHz genuine

Allows use in systems requiring short output time constants

DSP lock-in amplifiers

without problems caused by an insufficient number of samples
per signal cycle

Analog outputs updated at 7.5 MHz for use

Ideal for scanned probe microscopy feedback control loops

with time constants down to 1 µs

Spectral Display (Model 7280 only)

See in the frequency domain where interfering signals are and
choose a quiet region for your reference frequency

Dual Reference

Measure two signals at two different frequencies simultaneously,
without the expense involved in buying two instruments

Dual Harmonic

Measure two signals at two different harmonics simultaneously,
without the expense involved in buying two instruments

Curve Buffer Graphical Display

Strip chart mode display is invaluable for monitoring during
manual adjustment of experiments

Virtual Reference

Recover signals even without a reference

Large high resolution electroluminescent display

Excellent viewing angle for good visibility even across a

(Model 7280 only)

crowded laboratory

Easy to set controls with keypad and

Enter the exact setting you need without having to fiddle with a

cursor movement keys (Model 7280 only)

sensitive rotary knob. Move the cursors on the graphical display
with ease

User upgradeable firmware

Benefit from future firmware upgrades without having to send the
instrument to a service facility

2-input multiplexing using A and -B inputs

Measure two signals sequentially under computer control using

- even under computer control

the same lock-in without having to switch connections

8 User Settings Memory (Model 7280 only)

Several users can share an instrument but keep their own
personalized settings

Internal Oscillator can be used independently

Set OSC OUT to a different frequency to the reference e.g. Use

of rest of instrument

it to control a SIGNAL RECOVERY chopper at f and then
connect the lock-in's reference input to the chopper's f/10 SYNC
output

Auxiliary Digital Input and Output port

Eliminate the need for separate digital I/O cards when building
complex computer controlled experiments

Excellent LabVIEW driver

Saves programming time

Compatible with Acquire software

Eliminates the need to develop programs

Compatible with SRInstComms

Control the instrument from any ActiveX enabled programming
language, such as Visual Basic, VBA (Excel, Word, Access)
and VBScript (Internet Explorer)

Lock-in Amplifiers

Why should you choose

SIGNAL RECOVERY

products?

Models 7280 and 7280BFP Wide Bandwidth DSP Lock-in Amplifiers

SIGNAL RECOVERY

Product Features

Benefit to you