Series el model table – Atec Kepco-EL Series User Manual
Page 3
KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11355 USA • Tel: (718) 461-7000 • Fax: (718) 767-1102
Email: [email protected] • www.kepcopower.com
Model EL 1K-200-100D
Model EL 2K-200-200
SERIES EL MODEL TABLE
OPERATING LIMITS
OVERLOAD PROTECTION
RATED POWER
Watts
RATED VOLTAGE
Volts
RATED CURRENT
ALL MODES
Amps
POWER
(3)
Watts
VOLTAGE
(3)
Volts
CURRENT
(4)
Amps
MINIMUM ON
RESISTANCE
ALL MODES
Ohms
MODEL NUMBER
(1)(2)
EL 1K-50-125
(5)
EL 1K-200-100
(5)
EL 1K-400-70
(5)
EL 1K-600-30
(5)
EL 2K-50-250
(5)
EL 2K-200-200
(5)
EL 2K-400-140
(5)
EL 2K-600-60
(5)
EL 3K-50-400
EL 3K-200-300
EL 3K-400-210
EL 3K-600-90
EL 4K-50-600
EL 4K-200-500
EL 4K-400-350
EL 4K-600-150
EL 5K-50-800
EL 5K-200-600
EL 5K-400-420
EL 5K-600-200
1000
1000
1000
1000
2000
2000
2000
2000
3000
3000
3000
3000
4000
4000
4000
4000
5000
5000
5000
5000
50
200
400
600
50
200
400
600
50
200
400
600
50
200
400
600
50
200
400
600
125
100
70
30
250
200
140
60
400
300
210
90
600
500
350
150
800
600
420
200
1050
1050
1050
1050
2100
2100
2100
2100
3150
3150
3150
3150
525
2100
4200
4200
5250
5250
5250
5250
52.5
210
420
630
52.5
210
420
630
52.5
210
420
630
52.5
210
420
630
52.5
210
420
630
135
105
73.5
31.5
265
210
147
63
420
315
220.5
94.5
630
525
367.5
157.5
835
630
441
210
0.006
0.014
0.046
0.017
0.004
0.007
0.023
0.083
0.0035
0.005
0.015
0.056
0.002
0.003
0.009
0.033
0.002
0.002
0.008
0.028
INPUT
IMPEDENCE
Ohms
80K
160K
200K
320K
80K
160K
200K
320K
80K
160K
200K
320K
80K
160K
200K
320K
80K
160K
200K
320K
(1) For GPIB interface, add suffix "G" to the model number. The GPIB interface is in addition to the standard rS-232 and uSB interfaces, except for dual channel
models the GPIB interface replaces the standard rS-232 and uSB interfaces.
(2) For Ethernet interface (in addition to the standard rS-232 and uSB interfaces), add suffix "E" to the model number.
(3) Maximum operating power and/or current may be reduced when ambient temperature exceeds 35°C depending on air flow, duty cycle of load operation and
other situational specific conditions.
(4) Each FET is individually fused. Blown fuses are reported in unit status.
(5) For dual channel models (these models include two completely independent loads in a single chassis) add suffix "D" to the model number. Specifications listed
are per channel for dual channel models.
1000 WATT MODELS AND 1000 WATT DUAL CHANNEL MODELS
(5)
2000 WATT MODELS AND 2000 WATT DUAL CHANNEL MODELS
(5)
3000 WATT MODELS
4000 WATT MODELS
5000 WATT MODELS