beautypg.com

Specifications – Atec NHResearch-4600 Series User Manual

Page 4

background image

NH Re search, Incorporated
16601 Hale Avenue, Irvine, California 92606
Tel: 949-474-3900
Fax: 949-474-7062
www.nhresearch.com
www.electronicloads.com

©Copyright 2009, NH Research Incorporated.
All rights reserved.
Specifications subject to change without notice.

SPECIFICATIONS

1

4600 Ratings

4600-3

4600-6

4600-12

4600-18

4600-24

4600-36²

Power

3 kW

6 kW

12 kW

18 kW

24 kW

36 kW

Maximum Current³

30 A

60 A

120 A

180 A

240 A

360 A

Voltage Range³

50 - 350 V

50 - 350 V

50 - 350 V

50 - 350 V

50 - 350 V

50 - 350 V

Programmable

Modes

Constant Current

Range (RMS)

0 - 30 A

0 - 60 A

0 - 120 A

0 - 180 A

0 - 240 A

0 - 360 A

Accuracy

0.2%

0.2%

0.2%

0.2%

0.2%

0.2%

Resolution

0.05%

0.05%

0.05%

0.05%

0.05%

0.05%

Constant Voltage

Range

50 - 350 V

50 - 350 V

50 - 350 V

50 - 350 V

50 - 350 V

50 - 350 V

Accuracy

0.2%

0.2%

0.2%

0.2%

0.2%

0.2%

Resolution

0.05%

0.05%

0.05%

0.05%

0.05%

0.05%

Constant Power

Range

300 W - 3 kW

600 W - 6 kW

1.2 - 12 kW

1.8 - 18 kW

2.4 - 24 kW

3.6 - 36 kW

Accuracy

0.5%

0.5%

0.5%

0.5%

0.5%

0.5%

Resolution

0.05%

0.05%

0.05%

0.05%

0.05%

0.05%

Constant Resistance

Ranges

2.5-100, 100-1000Ω 1.25-50, 50-500Ω 0.63-25, 25-250Ω 0.42 -17, 17-167Ω 0.31-12.5, 12.5-125Ω 0.2-8.3, 8.3-83Ω

Accuracy

1, 5%

1, 5%

1, 5%

1, 5%

1, 5%

1, 5%

Resolution

0.05%

0.05%

0.05%

0.05%

0.05%

0.05%

Short Circuit

Max Surge Current 300 A

600 A

1200 A

1800 A

2400 A

3600 A

Power Factor

Range

0 -1, lead/lag

0 -1, lead/lag

0 -1, lead/lag

0 -1, lead/lag

0 -1, lead/lag

0 -1, lead/lag

Accuracy

1%

1%

1%

1%

1%

1%

Resolution

0.05%

0.05%

0.05%

0.05%

0.05%

0.05%

Crest Factor

Range

1.414 - 4

1.414 - 4 1.414 - 4

1.414 - 4

1.414 - 4

1.414 - 4

90 A limit

180 A limit

360 A limit

540 A limit

720 A limit

1080 A limit

Accuracy

1%

1%

1%

1%

1%

1%

Resolution

0.05%

0.05%

0.05%

0.05%

0.05%

0.05%

Macros

Queues of up to 100 commands can be run manually or from a triggered event

such as phase angle, input voltage level, or system trigger

Custom Waveforms

User-defined waveforms can be created through a full-screen graphical editor that provides control

of current, voltage, resistance, power, crest factor and power factor

Measurements

Current

Ranges (RMS)

0 - 30 A

0 - 60 A

0 - 120 A

0 - 180 A

0 - 240 A

0 -360 A

Accuracy

0.2%

0.2%

0.2%

0.2%

0.2%

0.2%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

Peak Current

Ranges

0 - 90 A

0 - 180 A

0 - 360 A

0 - 540 A

0 - 720 A

0 - 1080 A

Accuracy

0.5%

0.5%

0.5%

0.5%

0.5%

0.5%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

Voltage

Ranges

50 - 350 V

50 - 350 V

50 - 350 V

50 - 350 V

50 - 350 V

50 - 350 V

Accuracy

0.1%

0.1%

0.1%

0.1%

0.1%

0.1%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

Peak Voltage

Ranges

50 - 500 V

50 - 500 V

50 - 500 V

50 - 500 V

50 - 500 V

50 - 500 V

Accuracy

0.5%

0.5%

0.5%

0.5%

0.5%

0.5%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

Frequency

Range

45 - 440 Hz

45 - 440 Hz

45 - 440 Hz

45 - 440 Hz

45 - 440 Hz

45 - 440 Hz

Accuracy

0.1%

0.1%

0.1%

0.1%

0.1%

0.1%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

True Power

Ranges

0 - 10.5 kVA

0 - 21 kVA

0 - 42 kVA

0 - 63 kVA

0 - 84 kVA

0 - 126 kVA

Accuracy

0.2%

0.5%

0.5%

0.5%

0.5%

0.5%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

Apparent Power

Range

0 - 10.5 kVA

0 - 21 kVA

0 - 42 kVA

0 - 63 kVA

0 - 84 kVA

0 - 126 kVA

Accuracy

0.3%

0.3%

0.3%

0.3%

0.3%

0.3%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

Reactive Power

Range

0 - 10.5 kVA

0 - 21 kVA

0 - 42 kVA

0 - 63 kVA

0 - 84 kVA

0 - 126 kVA

Accuracy

0.3%

0.3%

0.3%

0.3%

0.3%

0.3%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

Peak Power

Range

0 - 45 kW

0- 90 kW

0 - 180 kW

0 - 270 kW

0 - 360 kW

0 - 540 kW

Accuracy

1.0%

1.0%

1.0%

1.0%

1.0%

1.0%

Resolution

0.1%

0.1%

0.1%

0.1%

0.1%

0.1%

Resistance

Range

2.5-100, 100-1000Ω 1.25-50, 50-500Ω 0.63-25, 25-250Ω

0.42-17, 17-167Ω 0.31-12.5, 12.5-125Ω 0.2-8.3, 8.3-83Ω

Accuracy

1%, 5%

1%, 5%

1%, 5%

1%, 5%

1%, 5%

1%, 5%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

Crest Factor

Range

1.414 - 4

1.414 - 4

1.414 - 4

1.414 - 4

1.414 - 4

1.414 - 4

Accuracy

0.5%

0.5%

0.5%

0.5%

0.5%

0.5%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

Power Factor

Range

0 -1, lead/lag

0 -1, lead/lag

0 -1, lead/lag

0 -1, lead/lag

0 -1, lead/lag

0 -1, lead/lag

Accuracy

0.5%

0.5%

0.5%

0.5%

0.5%

0.5%

Resolution

0.01%

0.01%

0.01%

0.01%

0.01%

0.01%

Waveform Display

Continuously updated, graphical display of a full cycle of current, voltage and/or power waveforms

Physical

Enclosure

Chassis

Chassis (2)

Cabinet

Cabinet

Cabinet, 2-Bay

Cabinet, 2-Bay

Dimensions (HxWxD) 8¾ x 19 x 23 in 17½ x 19 x 25 in 57 x 23 x 30 in

72 x 23 x 30 in 57 x 46 x 30 in

72 x 46 x 30 in

23 x 49 x 59 cm

45 x 49 x 64 cm 145 x 59 x 77 cm

183 x 59 x 77 cm 117 x 59 x 77 cm

183 x 117 x 77 cm

Weight

77 lbs / 35 kg

154 lbs/70 kg

440 lbs/200 kg

650 lbs/295 kg

860 lbs/391 kg

1250 lbs/568 kg

Control
User Interface

PC soft panel

PC

3 GHz µP with 512 MB

RAM, SVGA display, 80 GB HD

OS

Window XP

Test Executive

Optional emPower™ LE

Communications

RS-232, USB option

Drivers

NI LabVIEW, IVI, Active X

Additional

Features
3-Phase

Provides for control of 3

Operation

individual units (for example,

3kVA units for a total of 9kVA,

6kVA units for a total of
18 kVA) to simulate a 3-phase

load

Remote Voltage

1 MegaOhm impedance, 2 VDC

Sense

max drop between sense and

load input

Self Test

Power-up self test of all major

functions including status of

input, output, control and
protection circuits

Performance

Continuous checking of

Monitoring

performance parameters and

appropriate error messages

and/or LED fault indicators

Calibration

Closed cover, all adjustments
made in software and stored in

FLASH

Protection

OP, OC, OV, OT, and
Undervoltage

Lockout

Trigger Output

To initiate an external
measurement device and
synchronized to programmed
load current step

Fan Noise

Automatic fan speed control

Reduction
Load Connectors

ITT Cannon DCM-
21WA4P/DM 53745-1 plug
& socket

Operating

0 - 50° C, maximum continuous

Temperatue

and peak power derated 20%
above 38° C

Input Power

115/230 ± 10% VAC, 47 - 63 Hz

¹Specifications apply at 23* +/- 5* C after a 10 minute

warm up and are subject to change without notice.

All Accuries and Resolutions are % of full scale
²Higher power and custom configurations available
³Accuracies apply when Settings and/or Measurements

>10% of Range

1_NHR 4600 D.S.:NHR 4600 D.S. 8/20/09 11:02 AM Page 4