beautypg.com

Selection table, Ordering information, Test tools – Atec Fluke-199C User Manual

Page 5

background image

Selection Table

Fluke 199C

Color ScopeMeter (200 MHz / 2.5 GS/s)

Fluke 199C/S

Color ScopeMeter (200 MHz / 2.5 GS/s) + SCC190

Fluke 196C

Color ScopeMeter (100 MHz / 1 GS/s)

Fluke 196C/S

Color ScopeMeter (100 MHz / 1 GS/s) + SCC190

Fluke 199B

ScopeMeter (200 MHz / 2.5 GS/s)

Fluke 199B/S

ScopeMeter (200 MHz / 2.5 GS/s) + SCC190

Fluke 196B

ScopeMeter (100 MHz / 1 GS/s)

Fluke 196B/S

ScopeMeter (100 MHz / 1 GS/s) + SCC190

Fluke 192B

ScopeMeter (60 MHz / 500 MS/s)

Fluke 192B/S

ScopeMeter (60 MHz / 500 MS/s) + SCC190

Fluke 125

Industrial ScopeMeter (40 MHz, with Bus Health)

Fluke 125/S

Industrial ScopeMeter (40 MHz, Bus Health) + SCC120 kit)

Fluke 124

Industrial ScopeMeter (40 MHz)

Fluke 124/S

Industrial ScopeMeter (40 MHz) + SCC120 kit

Fluke 123

Industrial ScopeMeter (20 MHz)

Fluke 123/S

Industrial ScopeMeter (20 MHz) + SCC120 kit

SCC190

FlukeView

®

Software + Cable + Case (190 Series)

SCC120

FlukeView

®

Software + Cable + Case (120 Series)

OC4USB

Optically-isolated USB-interface cable

PM9080

Optically-isolated RS-232 adapter/cable

SW90W

FlukeView

®

ScopeMeter Software for Windows

®

ScopeMeter test tools come standard with a complete accessory package including line

voltage adapter and battery pack (installed). ScopeMeter 190B and 190C Series come

with probes, probe accessories and multimeter test leads.

Optional accessories ordering information can be found in the technical datasheet or

on the Fluke web site.

Ordering information

Bandwidth
Max. real time sample rate
Equivalent time sample rate
Max. record length (per input)
Number of inputs
Input sensitivity
Independently floating
isolated inputs

Display and Display Modes

Display
Persistence

Envelop Mode
Waveform compare
FFT

Pass/Fail testing

Triggering

Connect-and-View™ Triggering

Edge, single, free run
Video
Video line select
Pulse width
External

Advanced Functions

Cursors
Zoom
Dual Input TrendPlot™
ScopeRecord™ Mode
Automatic capture and replay
of last 100 screens
Bus Health test mode
Advanced Power
Measurements
Waveform mathematics
Save set-ups and screens
True-rms multimeter

Safety, Power and Warranty

Safety (EN61010-1)
Battery
Line power
PC and printer interface
Warranty

190C ScopeMeter Series

190B ScopeMeter Series

10 Series

Fluke 199C

Fluke 19C

Fluke 199B

Fluke 19B

Fluke 19B

Fluke 1

Fluke 1

Fluke 1

200 MHz

100 MHz

200 MHz

100 MHz

60 MHz

40 MHz

40 MHz

20 MHz

2.5 GS/s

1.0 GS/s

2.5 GS/s

1.0 GS/s

500 MS/s

25 MS/s

25 MS/s

25 MS/s

(covered by real time sample rate)

2.5 GS/s

2.5 GS/s

1.25 GS/s

3000 points

512 points (min/max pairs)

2 scope inputs, 1 DMM input (all fully isolated from each other)

2 scope or DMM inputs

2 mV/div. to 100 V/div.

5 mV/div. to 100 V/div.

5 mV/div. to 50 V/div.

Color

Monochrome

Monochrome

Digital persistence with

On/Off

variable decay

visual + automatic

visual only

h

armonics

mode

Using optional ITP120

10

10

20

20

10

5000 counts, measures volts – amps – ohms – continuity – diode – temperature

1000 V CAT II / 600 V CAT III certified

600 V CAT III certified

(1)

4 hours, NiMH

7 hours, NiMH

Adapter/battery charger included

Using optional Optically Isolated interface cable (either RS-232 or USB) or PAC91 printer adapter cable

Three years on instrument / One year on standard accessories

(1)

Maximum input voltage 1000 V CAT II with VPS40, 40 MHz, 10:1 Voltage Probe (standard included with Fluke 125 and Fluke 124)

Detailed technical specifications and optional accessories can be found in the technical datasheet and on the Fluke web site.

10 and 190 Series ScopeMeter

®

Test Tools

Fluke Corporation

PO Box 9090,

Everett, WA USA 98206

Fluke. Keeping your world up and running.

Fluke Europe B.V.

PO Box 1186, 5602 BD

Eindhoven, The Netherlands

For more information call:

In the U.S.A. (800) 443-5853 or Fax (425) 446-5116

In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222

In Canada (800)-36-FLUKE or Fax (905) 890-6866

From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116

Web access: http://www.fluke.com

©2004, 2007 Fluke Corporation. All rights reserved.

Specifications subject to change without notice.

Printed in U.S.A. 2/2007 1629090 B-EN-N Rev E