beautypg.com

Scopemeter, 190 series, Scopemeter special value kit – Atec Fluke-199C User Manual

Page 3: Flukeview, Software for documenting, archiving and analysis

background image

ScopeMeter special value kit

FlukeView Software and the optically isolated

interface cable come as separate items, or as part of

the special value SCC-Kit. This kit contains:

FlukeView Software (SW90W)

Optically Isolated Interface Cable (for USB)

Protective Hard-Shell Carrying Case (C190 or C120)

The SCC-kit can be ordered separately, or

with the main instrument by adding an “S”

to the main instrument type number, e.g.,

Fluke 199C/S (see Ordering Information

on back cover for more detailed information).

SCC120 Kit

SCC190 Kit

ScopeMeter

®

190 Series

The inrush current is measured on the part of

the waveform enclosed by the cursors.

Cursor-limited
automatic measurement

ScopeMeter 190C and 190B features

30 automatic measurements, cursors,

zoom and real-time clock. Now auto-

matic power and Vrms-measurements

can be performed on a specific, user

identified portion of the waveform

using the cursors of the Fluke 190C

to define the time-window of inter-

est. In this way, the ScopeMeter 190C

measures the power within a specified

time span, or the rms-value of a volt-

age during a dedicated period of time.

Pass/Fail testing of actual signal against a

reference template

Waveform Pass/Fail Testing

“Waveform reference” allows an acquired

trace to be stored and designated “refer-

ence trace” for visual comparisons, or it

can be used as the reference for auto-

matic “Pass/Fail” testing (190C). Up to

100 individually matching (“Pass”) or

non-matching (“Fail”) waveforms can be

stored in the replay memory, allowing

you to monitor your system‘s behav-

ior over a long period of time, without

having to be present!

Automatic capture and replay
of 100 screens

Scope users know how frustrating it is to

see a one-time anomaly flash. Not with

the ScopeMeter 190 Series! Now you can

look back in time with a touch of the

replay button. In normal use, the instru-

ment continuously memorizes the last

100 screens. Each time a new screen is

acquired, the oldest is discarded. At any

moment, you can “freeze” the last 100

screens and scroll through picture-by-

picture or replay as a “live” animation.

Cursors can be used for further analysis.

Use the advanced trigger capabilities

to capture up to 100 specific events.

Two sets of 100 captured screens with

individual time stamps can be stored for

later recall or download to a PC.

Measure from mV to kV—
fully isolated and safely!

The ScopeMeter 190C and 190B series

have three independently floating

isolated inputs. While conventional

oscilloscopes can only make measure-

ments referenced to the line power

ground, measurements on each of the

Fluke ScopeMeter 190 series inputs

can be referenced to a different “low”

level. This enables measurements in

mixed circuits having different ground

references, and also eliminates the risk

of accidental ground short circuits. All

inputs are safety certified for measure-

ments in 1000 V CAT II and 600 V

CAT III environments. And the standard

probes cover a wide application range

from mV to kV, making the 190C and

190B ScopeMeter ideal for micro elec-

tronics to electrical applications.

Use the 27,500 points memory of ScopeRecord

and zoom in for maximum detail.

Deep memory for high-resolution
ScopeRecord™

The ScopeRecord memory stores 27,500

points per input or more, for high-

resolution recording of events up to 48

hours, and captures fast intermittents

and glitches as short as 50 ns. This

continuous roll mode stores events like

motion profiles, UPS, power supply and

motor start-ups. All models also have

a “Stop-on-Trigger” in the ScopeRecord

mode, allowing the ScopeMeter to store

waveform data until the instrument

is triggered or until a repetitive trigger

signal is interrupted. This way,

the instrument will automatically

recognize a power failure and store the

waveform data preceding it. With

100 x zoom, you can look at the small-

est details, like individual power cycles.

Two of these 27,500 point record-

ings can be stored for later analysis.

Vpwm measures effective voltage on motor drive

and frequency inverter outputs.

Cursors and zoom featured by the 190 Series

help you to analyze the captured TrendPlot.

Use TrendPlot

to help

find intermittents, fast

The toughest faults to find are those

that happen only once in a while

—intermittents. They can be caused by

bad connections, dust, dirt, corrosion

or simply broken wiring or connectors.

Other factors, like line outages and sags

or the starting and stopping of a motor,

can also cause a machine to stop. You

may not be around to see it your Fluke

ScopeMeter will. In this “paperless

recorder” mode, you can plot the mini-

mum and maximum peak values and

average over time up to 16 days. The

two inputs can plot any combination

of volts, amps, temperature, frequency

and phase – with time and date stamp

—to help lead you to the cause of those

faults quickly.

Connect-and-View captures even

the most complex motor drive signals.

Connect-and-View

triggering for an
instant, stable display

Scope users know how difficult trig-

gering can be. Incorrect settings show

unstable and sometimes incorrect

results. The unique Connect-and-View

function recognizes signal patterns and

automatically sets up correct triggering.

It provides a stable, reliable and repeat-

able display of virtually any signal,

including motor drive and control

signals, without touching a button.

Signal changes are instantly recog-

nized and settings adjusted for a stable

display. Benefit from the speed and

convenience when measuring a number

of test-points in quick succession.

FlukeView

®

Software for

documenting,

archiving and

analysis

FlukeView for Windows

®

helps you get more out of
your ScopeMeter by:

Documenting – transfer waveforms,

screens and measurement data from

the ScopeMeter to a PC. Print or

import the data into your report.

Adding user text to individual

ScopeMeter settings – provid-

ing guidance to the operator when

recalling a set-up.

Archiving – create a library of

waveforms with your comments

for easy reference and comparison.

Store complete Replay cycles for

analysis of waveform changes.

Store complete memory content of

the ScopeMeter on your PC for

back-up purposes.

Waveform compare – store refer-

ence waveforms, add operator

instructions, and send both to the

ScopeMeter for waveform compari-

son and “Pass/Fail” testing.

Analysis – use cursors, perform

spectrum analysis or export data to

other analysis programs.

Connection to a PC via an optically

isolated interface cable

Software and cable come as separate

items or as part of a special value

kit. This kit also includes a protective

hard shell carrying case for safe and

convenient storage of instrument and

accessories.

ScopeMeter

®

120 and 190 Series common functions