2 Fluke Corporation ScopeMeter 190 Series II

2 Fluke Corporation ScopeMeter 190 Series II

Oscilloscope modes

190-062

190-102

190-202

190-502

190-104

190-204

Vertical deflection

Number of channels

2

2

2

2

4

4

Bandwidth

60 MHz

100 MHz

200 MHz

500 MHz

100 MHz

200 MHz

Rise time

5.8 ns

3.5 ns

1.7 ns

0.7 ns

3.5 ns

1.7 ns

Number of scope inputs

2 input channels plus external trigger

4 input channels

Channel architecture

All inputs fully insulated from each other and from ground

Inputs may be activated in any combination

Input coupling

AC or DC, with ground level indicator

Input sensitivity

2 mV/div to 100 V/div, plus variable attenuation

Bandwidth limiter

User selectable: 20 kHz, 20 MHz or full bandwidth

Normal/invert/variable

On each input channel, switched separately

Input voltage

CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details

Vertical resolution

8 bit

Accuracy

± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div

Input impedance

1 MΩ ± 1 % // 14 pF ± 2 pF

Horizontal

Maximum real-time sample

rate (sampled simultaneously)

625 MS/s for

each channel

1.25 GS/s for

each channel

2.5 GS/s (2ch)

5 GS/s (single

channel) or 2.5

GS/s (on 2ch)

1.25 GS/s for

each channel

2.5 GS/s (2ch)

1.25 GS/s (4ch)

Record length

Up to 10,000 samples per channel

Time base range

10 ns/div

to 4 s/div

5 ns/div

to 4 s/div

2 ns/div

to 4 s/div

1 ns/div.

to 4 s/div.

5 ns/div

to 4 s/div

2 ns/div

to 4 s/div

Time base in a 1-2-4-sequence

Slower time/division settings using ScopeRecord

Roll mode (see ‘Recorder mode’)

Maximum record length

10,000 samples per channel in scope mode;

30,000 points per channel in ScopeRecord

Roll mode (see ‘Recorder mode’)

Timing accuracy

± (0.01 % of reading + 1 pixel)

Glitch capture

8 ns peak detect on each channel

(using real time sampling and data compression, at any timebase setting)

Display and acquisition

Display

153 mm (6 in) full-color LCD with LED backlight

Display modes

Any combination of channels; average on/off; replay

Visible screen width

12 divisions horizontally in scope mode

Digital persistence modes

off/short/medium/long/infinite and envelope mode

Waveform mathematics

One mathematical operation on any 2 input channels: add/subtract/multiply; X-Y-mode

Frequency Spectrum using FFT analysis

Acquisition modes

Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture,

waveform compare with automatic “Pass/Fail testing”; Replay

Trigger and delay

Source

Input A, B or External (via meter input)

Input A, B, C or D

Modes

Automatic Connect-and-View

, free run, single shot, edge, delay, dual slope,

video, video line, selectable pulsewidth (channel A only), N-cycle

Connect-and-View

Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts

triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals

like motor drive and control signals. Can be switched off if preferred.

Video triggering (on ch. A)

NTSC, PAL, PAL+, SECAM; Includes field 1, field 2 and line select

High-res, non-interlaced video Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
Pulse width triggering

(on channel A)

Pulse width qualified by time

Allows for triggering t, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns

Time delay

1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay

Dual slope triggering

Triggers on both rising and falling edges alike

N-cycle triggering

Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99