Atec Noiseken-LSS-6230 User Manual
Lss-6230, Lightning surge simulator
●
●
●
●
●
●
●
●
●
Specification
Lightning Surge Simulator
LSS-6230
Parameter
■ Common
Polarity
Interval
No. of output setting
■ Surge generating unit
1.2/50μs-8/20μs
Combination waveforms
0.5μs-100kHz
Ring wave
Coupling network
Decoupling coil
AC EUT power capacity
DC Eat power capacity
Phase angle control
■ Surge generating unit for external CDN
10/700μs-5/320μs
Combination waveforms
■ Other
Voltage monitor
Current monitor
External communication
Power supply
Dimension
Mass
Specification
Positive / Negative
(Minimum charging time) ∼999 sec. 1 sec. step
1∼999 times 1 time step
Voltage surge
Current surge
Minimum charge time
Output impedance
Voltage surge
Current surge
Minimum charge time
Output impedance
Line - Line : 18μF, Line - PE : 10Ω+9μF, Line - PE simultaneous coupling (L+N-PE) : 9μF/9μF
1.5mH
Single phase AC 240V 16A MAX (50/60Hz)
DC125V/16A MAX
0∼360°
±10°
, Based on set injection / return angle
Voltage surge
Current surge
Minimum charge time
Output impedance
BNC output, 1/1000±10%
BNC output, 1mV/A±10%
RS-232C optical communication
AC100V ∼120V±10%, AC200V ∼240V±10%,50/60Hz Power consumption : Less than 300VA
W430×H515×D500 mm(Projection excluded)
Approx. 65kg
Output voltage
Front time
Duration
Output current
Front time
Duration
Output voltage
Rise time
Frequency
2nd peak voltage
3rd peak voltage
4th peak voltage
Output voltage
Front time
Duration
Output current
Front time
Duration
0.5∼6.0kV ±10%
1.2μs±30%
50μs±20%
250∼3000A ±10%
8μs±20%
20μs±20%
10 Sec.
2Ω±10%
0.5∼6.0kV ±10%
0.5μs±0.15μs
100kHz±20kHz
40-110% of 1st peak voltage
40-80% of 2nd peak voltage
40-80% of 3rd peak voltage
5 Sec.
12 Ω±3 6 Ω at 12 Ω selection in interruptive resistance
30 Ω±8 Ω at 30 Ω selection in interruptive resistance
0.5∼6.0kV ±10%
10μs±30%
700μs±20%
12.5∼150A ±10%
5μs±20%
320μs±20%
15 Sec.
40Ω±10%
w w w . n o i s e k e n . c o m
Lightning Surge Simulator
Conforming to IEC61000-4-5 ed2 Standard
Ring wave conforming to ANSI/IEEE C62.45 available
Max. voltage 6.6kV output focusing on the practical use
Monitor terminal standard equipped so as for easy waveform pre-checking
Interlock built-in as the emergency stop function for safety
Remote control software from PC ready as the option besides the stand-alone operation
AC/DC CDN standard equipped. Available up to 3-phase AC500V 50A as the option
CDN for Telecom lines, CDN for interconnection lines, isolation transformer, etc. ready as
the option