Technical Specifications
PSURGE 30.2 Mainframe
Charging voltage range
3...33kV
Test cabinet
39 x 29 x 32 cm (W x D x H)
Capacitors
9uF / 36uF
HV switch
triggered spark gap
Stored energy
5kJ at max. charging
voltage
Impulse polarity
positive, negative,
alternating
HV output
terminals inside the test
cabinet
Impulse circuit
floating, max. voltage
between common and
ground 500V AC
Power mains
208, 230 or 240V
50/60Hz, 1800VA
External synchronisation
0°....360° in 1° steps
Weights and Dimensions (W x D x H, net weight)
PSURGE 30.2
60 x 100 x 190 cm
approx. 320 kg
Impulse Module PS30-CW
Impulse type
Combination wave
Output impedance
2 Ohm
Voltage front time
1.2us
±
30%
Current front time
8us
±
20%
Voltage decay time
50us
±
20%
Current decay time
20us
±
20%
Voltage undershoot
≤
30%
Current undershoot
≤
30%
Voltage amplitude range
3...30kV
Current amplitude range
1.5...15kA
Impulse repetition
up to 6 impulses per
minute at max. voltage
Impulse Module PS30-8x20
Impulse type
current
Output impedance
0.5 Ohm
Voltage front time
not defined
Current front time
8us
±
20%
Voltage decay time
not defined
Current decay time
20us
±
20%
Undershoot
not defined
Undershoot
≤
20%
Charging voltage range
3...15kV
Current amplitude range
6...30kA
Impulse repetition
up to 2 impulses per
minute at max. current
Impulse Module PS30-10x350
Impulse type
current
Output impedance
12 Ohm
Voltage front time
not defined
Current front time
10us
±
20%
Voltage decay time
not defined
Current decay time
350us
±
20%
Charging voltage range
3...15kV
Current amplitude range
240...1200A
Impulse repetition
up to 2 impulses per
minute at max. current
Impulse Module PS30-10x1000
Impulse type
current
Output impedance
37 Ohm
Voltage front time
not defined
Current front time
10us
±
20%
Voltage decay time
not defined
Current decay time
1000us
±
20%
Charging voltage range
3...15kV
Current amplitude range
80...400A
Impulse repetition
up to 2 impulses per
minute at max. current