Application software, Optional components – Atec Kikusui-KES4022A User Manual
Page 3

3
[Application Software]
(Remarks) The execution or aborting the test can not be controlled remotely from the PC. This software can not be used for the KES4021A.
The KES4022A includes a dedicated application software as a standard accessory. The test conditions can be set
either from the front panel or through by the PC. Moreover, the specifi ed condition of the parameter can be easily
entered in the excel format as it activates as macro program.
[System requirement]
●
Interface : RS232C
●
OS : Windows XP Professional (SP2 or later, 32 bit version)
●
Application software : Microsoft Excel 2003 VBA
[Optional components]
●
Option parts for IEC61000-4-2 standard test
CR unit and discharge tip are available for the IEC61000-4-2 standard test.
Product name
Model name
CR unit (150 pF/330
Ω
) for IEC61000-4-2
CR31-KES
Air discharge tip(Resistance value 330
Ω
)
AT31-KES
Contact discharge tip(Resistance value 330
Ω
)
CT31-KES
●
Option parts for ISO 10605 standard test
CR unit and discharge tip are available for the ISO 10605 standard test.
Product name
Model name
CR unit(330pF/330)for ISO10605 Ed.2.0
CR32-KES
CR unit(150pF/2k)for ISO10605 Ed.2.0
CR33-KES
CR unit(330pF/2k)for ISO10605 Ed.2.0
CR34-KES
Air discharge tip(Resistance value 2k
Ω
)
AT32-KES
Contact discharge tip(Resistance value 2k
Ω
)
CT32-KES
Sphere discharge tip(Resistance value 330
Ω
)
ST31-KES
Sphere discharge tip(Resistance value 2k
Ω
)
ST32-KES
●
C Unit/Discharge Resistor
*
IEC61000-4-2 specifies the combination of the energy storage capacitor
and the discharge resistor. Changing the combinations of the C unit and the
discharge resistor can simulate various conditions
.
[C Unit ]
This unit is inserted into a discharge gun. It consists of the energy storing capacitor.
The discharge resistor(sold separately) must be connected for the operation.
Capacity
Model name
150pF
EC21-KES
100pF
EC22-KES
200pF
EC23-KES
250pF
EC24-KES
300pF
EC25-KES
330pF
EC26-KES
400pF
EC27-KES
500pF
EC28-KES
[Discharge Resistor]
Equipped inside the option C Unit to limit discharge current.
Resistance value
Model name
330
Ω
DR21-KES
100
Ω
DR22-KES
150
Ω
DR23-KES
200
Ω
DR24-KES
300
Ω
DR25-KES
400
Ω
DR26-KES
500
Ω
DR27-KES
1k
Ω
DR28-KES
1.5k
Ω
DR29-KES
2k
Ω
DR30-KES
5k
Ω
DR31-KES
10k
Ω
DR32-KES
10
Ω
DR33-KES
●
Discharge Gun Stand
The stand used to hold the discharge gun. It is convenient for discharging
electricity at the same point (vertical joint plate in particular).
Product name
Model name
Discharge gun stand
GS21-KES
●
Testing Environment Fixtures
EC61000-4-2 specifies the testing environment based on equipment type.
Required equipments for performing the electrostatic discharge immunity test
applied to the EUT
[ For Desktop Equipments ]
Fixtures for the test desktop equipment such as a PC.
Product name
Model name
Test table
TT21-KES
Ground reference plane*
GP21-KES
Horizontal coupling plane
ZC21-KES
Insulation sheet
IS21-KES
Vertical coupling plane (table-top)*
VC21-KES
Resistor cable
CL21-KES
*Optional resistance cable (model : CL21-KES) is required
[ For Floor-Standing Equipments ]
Fixtures for the test fl oor-standing equipment such as a rack mounted equipment.
Product name
Model name
Ground reference plane
GP21-KES
Vertical coupling plane (fl oor-standing)*
VC22-KES
Insulating support
IP21-KES
*Optional resistance cable (model : CL21-KES) is required
●
Waveform Measuring Instrument
The instrument used to measure the discharge current waveform defi ned in
IEC61000-4-2.
Product name
Model name
Current target (For Ed2.0)
Made-to-order
production
Target adapter line (For Ed2.0)
20dB Attenuator
Coaxial cable for high frequency (SMA-SMA)
Conversion Connector (SMA-BNC)
*Some combinations of the energy storage capacitor and the discharge resisitor may
shorten the life of the discharge-generating high-voltage switch of the discharge gun.
The complex setting of test condition can be easily made by entering the specified parameters.