Personal and Area Monitors

NBM-580 Broadband Radiation Meter

Specifications

NBM-580

DISPLAY
Display Type

TFT Active Matrix, Touchscreen

Display Size

6.95 inches, 156 x 82.8 mm, 800 x 480 pixels

Backlight

White LED’s

Display Refresh Rate

250 msec.

MEASUREMENT FUNCTIONS
Result Units

mW/cm

2

, W/m

2

, V/m, A/m, % of standard

Display Range

0001 to 9999, switchable between variable and permanent triads

Display Range, Variable Triads

0.01 V/m to 100.0 kV/m

0.01 mA/m to 265.3 A/m

0.001 mW/m

2

to 26.53 MW/m

2

0.1nW/cm

2

to 2.653 kW/cm

2

0.0001% to 9999%

Display Range, Fixed Triads

0.01 to 9999 V/m

0.0001 to 265.3 A/m

0.0001 to 9999 W/m

2

0.0001 to 9999 mW/cm

2

0.0001% to 9999%

Result Types (Isotropic, RSS)

Actual (ACT), Maximum (MAX), Minimum( MIN), Average (AVG),

Maximum Average (MAX AVG)

Result Types (X-Y-Z Mode)

Latest values: Actual X, Actual Y, Actual Z

(for probes with separate axis connections)

Time Averaging

Averaging time selectable from 4 s to 30 min (2 s steps)

Spatial Averaging

Individual or continuous sampling

Multi-Position Spatial Averaging

Averaging over up to 24 spatially averaged results, storage of individual position

results and of the total value

Progress Memory (History Mode)

Graphical display of the latest values versus time (time span 2 min to 8 h)

Correction Frequency

1 kHz to 100 GHz or OFF

(direct frequency selection, interpolation between calibration points)

Hot Spot Search

Acoustic indication of increasing or decreasing field strength

(Actual or Maximum)

Alarm Function

2 kHz warning tone (4 Hz repetition rate), variable threshold

Timer Controlled Recording

(Timer Logging)

Starting time setting: Up to 24 h in advance or record immediately

Recording time: up to 100 h

Store interval: Every 1s to 6 min (in 11 steps)

Number of store intervals: up to 32000

MEMORY
Memory

4 GB (expandable through USB Memory)

INTERFACES
Remote Operation Interface

Ethernet and IEEE-488.2 (Standard), RS-232 (Optional)

Sensor Connection 4 optical USB interfaces (serial, full duplex, 115200 baud, no parity,

1 start bit, 1 stop bit). 4 additional USB interfaces on rear panel.

Keyboard and Mouse

2 front panel USB interfaces

High Power Alarm Relays

Two user-configurable relays rated for 3 Amps at 115/130 VAC or 5 Amps at 30 V

GENERAL SPECIFICATIONS
Recommended Calibration Interval
24 months

a

Temperature Range

Operational: -10°C to +50°C

Non-operational (transport): -30°C to +70°C

Humidity

5 to 95% relative humidity, no condensation; ≤29 g/m³ absolute humidity

(IEC 60721-3-2 class 7K2)

Size

21 x 17 x 5.25 in. (53.4 x 43.2 x 13.4 cm) excluding rack mount angles

Weight

14.25 lbs. (6.46 kg)

Accessories Included

AC Power Cord, Manual, Calibration Certificate

NOTES: a Only for basic instrument; probes are specified separately