Ordering information, Guardian 5000 – Atec Quadtech-GUARDIAN-5000 User Manual
Page 2
![background image](/manuals/319008/2/background.png)
AC Output Voltage:
Range:
100V to 5000V AC
Resolution: 10 Volts / step
Frequency: 50/60 Hz selectable
Waveform: Sinusoidal
Regulation: +/-(1% of setting +5V)
Voltage Display:
Accuracy: +/-(1% of reading + 5V)
Resolution: 1Volt
AC Current Display:
Total current
Range: 0.001 to 40mA AC
Resolution: 0.001mA
Accuracy:+/-(1.5% of reading + 5cnt)
High/Low Limit Test:
1mA to 40mA AC
Accuracy: +/-(1% of limit +1mA)
Low limit can be turned OFF
ArcDetection:
Arc Level: >1mA to 40 mA & OFF in
0.001mA / Step
DC Output Voltage
Range:
100V to 6000V DC
Resolution: 10Volts / step
Regulation: +/-(1% of setting +5V)
Voltage Display:
Accuracy: +/-(1% of reading + 5V)
Resolution: 1Volt
DC Current Display:
Range:1mA to 20mA DC
Resolution: 0.001mA
Accuracy:+/-(1% of reading + 5cnt)
High/Low Limit Test:
0.001mA to 20mA DC
Low limit can be turned OFF
Arc Detection:
Arc Level: >1mA to 40 mA & OFF in
0.001mA / Step
Insulation Resistance
Range:
10M
Ω
- 10G
Ω
Accuracy:
+/- 5% >= 500V 10M
Ω
- 1G
Ω
+/-15% > 500V, 1G
Ω
- 10G
Ω
+/-10% < 500V, 1M
Ω
- 200M
Ω
+/- 15% < 200V, 200M
Ω
- 1G
Ω
Voltage Range:
50V to 1000V DC
Voltage Accuracy:
+/-(1% of setting +5V)
High/Low Limit Test:
10M
Ω
- 10G
Ω
High limit can be turned OFF
IR Test Delay:
0.3 to 99.9 seconds programmable in
0.1 second steps
Ground Bond
Output Current:
Range: 1.0 to 30.0A AC, setting
0.1A / step
Display:
+/-(1% of setting + 0.3A )
Frequency:
50 or 60Hz Selectable
No Load Voltage:
6 to 15 V programmable
Resistance:
Range: 0 - 500.0mV, 4 digits
Accuracy: +/- (1% of reading + 3 cnts)
Hi Limit:
10 mV to 510 mV
Offset Function:
0 to 100 mV, user selectable
Test Time:
0.5 - 999sec(+/-20ms)
Common Features
AC/DC Test Time:
Ramp: 0.1 to 99.9s (+/- 20ms)
Test: 0.1 to 999s (+/- 20ms) and
Continuous
Remote Control:
Inputs: Start,Stop
Characteristics: Optically Isolated with
+24V Active Low, Pulse Width >1ms.
Outputs: Pass/Fail/Under Test
Characteristics: Dry Contact relay
Ele. Characteristics: 120V 100mA max.
Logic: Closed if True
Connect: Terminal Strip & 9 pin D Serie
Test Setups:
50 Test Setups with 15 Steps each
Connectors:
Front Connection and Rear
Connections
Front Panel Lockout:
Password
Safety Features:
Fast Cutoff (<0.4ms) and Fast
Discharge
Miscellaneous:
Continuous Voltage on Fail
Scanner Delay: 0.1 to 99.9, 0.1s/step
Indication:
Pass/Fail lights, audible sound
Buzzer Level:
1,2,3 and Off
Standard Interface:
IEEE488
Optional Interface:
RS232
Data Bits: 8, Parity: None, Stop Bits: 1
Default Baud Rate: 9.6k
EOS: CR + LF, Echo: Off
Dimensions:
(w x h x d):17 x 6.8 x 17.7in
(430 x 175 x 450mm)
Weight:
53 lbs (24kg), Net
60 lbs (27kg), Ship
Environmental:
Operating: 0° to + 4°C
Humidity: <75%
Storage: - 10° to + 60°C
Power:
• 90 - 130V AC • 50 or 60Hz
• 200 - 250V AC • 300W max
Guardian 5000 Electrical Safety
Analyzer
Includes:
150206
Instruction Manual
700070
Power Cable
S02
Test Leads
G15
Ground Continuity Lead Set
Calibration Certificate Traceable to NIST
Optional Accessories:
Calibration Data
5000-01 Scanner, 8 Channel HV
5000-02 Scanner, 8 Channel HV/4GC
5000-03 Scanner, 8 Channel HV Rack
Mountable
5000-04 Scanner, 8 Channel HV/4GC
Rack Mountable
S04
HV Lead Set, 2m
S05
Foot Switch
S06
High Voltage Probe
S10
HV Lead, 2 meters, unterminated
S11
Gun Probe with remote start
S12
Load Box, resistive
S14
Load Box, custom resistors
S08
Gun Probe
S09
HV Lead, 1 meter, unterminated
G13
Corded Product Adapter
G14
Power Entry Adapter
G15
GC Lead Set, high &low
G16
International Power Strip
G22
Rear Panel Connection (factory
installed)
G23
Rack Mount Ears
G25
Corded Product Adapter (240V)
G26 RS232 Interface
Ordering Information
For more detailed specifications, visit
www.quadtech.com
For more information about special purchase, rent & lease options, call
1-800-253-1230
•
Fax 1-978-461-4295
•
Intl. 1-978-461-2100
5 Clock Tower Place, 210 East, Maynard MA 01754
P/N 030072/
A2
Guardian 5000