beautypg.com

Atec Hipotronics-100HVT Series User Manual

100 hvt series ac hipot tester

background image

100 HVT Series

AC Hipot Tester

Model 100 HVT

AC Hipot Tester

FEATURES

• Continuously adjustable output from

zero to full voltage

• Compact design

• Single end grounded high voltage test

transformer

• Separate guard and return

• Triple range current meter

• Triple range voltmeter

• Hand cart mounted

• Zero start interlock

• External interlock provision

• Input power circuit breaker

• Fast acting circuit breaker

• 50 kV tap for bucket liner testing.

BENEFITS

• Test to ANSI/SIA A92.2 1990

specifications

• Ideal for any high voltage AC insulation

test requirements

• Portable, for use in the field

• Safe and easy operation

• Low leakage current measurements

• Guard circuit eliminates stray leakage

current

APPLICATIONS

• Aerial platform hipoting

• Bucket truck hipoting

• Hot stick testing

• Rotating machinery testing

• Any high voltage AC test requirement

(within current limitations)

© Copyright 1996 Hipotronics Inc. All rights reserved.
Printed in USA

DESCRIPTION

The 100 HVT Series AC test sets are specifically designed to perform quick and
accurate AC dielectric tests.

The 100 HVT has a maximum output of 100 kV at 50 mA or 50 kV at 100 mA. This
test set can be used for testing bucket trucks and aerial platforms, hot sticks, blankets,
ropes or any other high voltage AC test requirement. They are particularly suitable for
meeting test procedures of the ANSI/SIA A92.2 1990 specification applied to the
insulating boom of work platforms and bucket trucks.

A triple range current meter enables low current readings of 0 to 1/10/100 mA on the
100 HVT. A triple range voltmeter is connected directly across the output for maximum
accuracy. The 100 HVT has a 50 kV tap that is used for bucket liner testing and other
low voltage, high current test requirements.

®

®

THE MEASURE OF A LEADER