Thumper specification review – Atec High-Voltage-CDS Series User Manual
Page 4
![background image](/manuals/318978/4/background.png)
4
CDS-3616U(F) & CDS-3632U(F) - The Network Systems Thumper
Input:
CDS-3616U/3632U:
120 V, 60 Hz, 25 A
CDS-3616UF/3632UF: 230 V, 50/60 Hz, 15 A
Hipot Output:
0 – 9/18/36 kVdc
Hipot Burn Current: 280/140/70 mAdc
Discharge Output:
CDS-3616U(F): 1600 Joules at each output voltage
CDS-3632U(F): 3200 Joules at each output voltage
Discharge Rate:
6 – 10 seconds
TDR Interface:
Arc Reflection & Current Impulse
Size:
25”w x 29”d x 44.5”h (30”w with attached cable reel)
635 mm w x 737 mm d x 1130 mm h
Weight:
1600J model: 375 lbs/170 kgs
3200J model: 450 lbs/204 kgs
Cable Outputs:
100’ HV, return, & ground
Cable Reels:
100’ HV & return cable reel
Optional
100’ ground cable reel
Thumper equipped with10’ output cable with
MC connection to reel
Other Features:
Rugged, transit protected meters
External Interlock
Emergency OFF mushroom switch
Plexiglas panel to view grounding solenoid
Internal heater to limit condensation
CDS-3616U(F) & CDS-3632U(F)
(suffix F for 230 V 50/60 Hz models)
These two models are ideal for Network Systems or other situations where cables are rated up to 69kV, oil insulated cables, and/or long
cable lengths are encounted. The powerful 3200 joule pulse makes fault locating easier using acoustical and electro-magnetic detection
devices. With 280 mA of burn current, faults can be rapidly reduced to low voltage levels, permitting thumping at lower and less damaging
voltage levels. The CDS-3632U can thump at 9kV, 18 kV, or 36 kV yet deliver 3200 joules.
There is no better thumper. The CDS-3616/32U offers the complete package: three full joule output voltages, three variable hipot
outputs, 280 mA burn current, variable discharge rate, tdr/radar ready, and its extremely durable design holds up to years of use.
Another plus: all HVI Thumpers use EPR high voltage output cable rather than XLPE. EPR stays flexible in cold weather. HVI thought
of everything.
Thumper Specification Review
Don’t handicap your fault finding efforts by buying a thumper with only half the features necessary.
For the same money, you can buy a full featured thumper. When specifying, require:
• At least two full joule output voltage settings, preferably three, and with at least 1000 joules of energy
• A variable hipot output with high burn current of at least 200mA
• Variable discharge rate from 6 – 10 seconds
• A remote TDR/radar, not one built-in, for flexibility, versatility, ease in service, and ease in use
Compare HVI Features and Specifications to Any Other – Why Utilities Choose HVI
Features
CDS-2010U
CDS-3616U
CDS-3632U
Output Voltages
0 – 5/10/20 kV
0 – 9/18/36 kV
0 – 9/18/36 kV
Joules
1000 @ 5/10/20 kV
1600 @ 9/18/36 kV
3200 @ 9/18/36 kV
Constant Energy
Yes. On all taps
Yes. On all taps
Yes. On all taps
Variable Hipot
Yes. On all taps
Yes. On all taps
Yes. On all taps
Hipot/Burn Rating
400 mA
280 mA
280 mA
Discharge Rate
6 – 10 seconds
6 – 10 seconds
6 – 10 seconds
TDR/Radar Ready
Yes
Yes
Yes
HVI Offers the Complete Package – Don’t Buy Less