Frequency Range

10 MHz to 2010 MHz

Accuracy

Same as Master Oscillator

Resolution

1 Hz (fc <20 MHz)

10 Hz (fc >20 MHz)

Minimum Level

-60 dBm (ANT connector)

Frequency Digital Meter Range

0 Hz to ±150 kHz

Bar Graph Meter Range

0 to ±100 kHz (in 4 decade ranges)

Accuracy

Same as Master Oscillator ± LSD

Resolution

1 Hz (±1 Hz to ±10 kHz)

10 Hz (>±10 kHz to ±150 kHz)

Minimum Level

-60 dBm (ANT Input Port)

Frequency Range

100 MHz to 2010 MHz

Input Level

0.05 mW to 50 W RMS (<900 MHz, 1–2–5

sequence, 4 decade)

0.05 mW to 10 W RMS (>900 MHz, 1–2–5

sequence, 4 decade)

Resolution

1 %

Accuracy

±6% (>5 W and <50 W, at Typical Operational

Ambient Temperature)

LOW LEVEL POWER METER
Frequency Range

Same as standard RF power meter

Input level

-40 dBm to -10 dBm

Accuracy

12% typical

Frequency Range

10 MHz to 2010 MHz

Sensitivity

<-80 for 10 dB SINAD

(1 kHz rate, 6 kHz Dev, FM 2, ANT Input Port)

Demodulation Output Level

(FM): 5 Vp-p ±15 % (at full scale into 600

)

(PM): 40 mVRMS ±15 % (5 Rad, into 600

)

(AM): 1 VRMS ±15 % (80 % modulation, into

600

)

(SSB): 1.15 VRMS ±15 % (Beat tone, into 600

)

Receive IF Output Signal Frequency

88 MHz to 90 MHz

IF Bandwidth

8.5 MHz

Deviation Range

±100 Hz to ±100 kHz

Resolution

100 Hz (20 kHz ranges)

1 kHz (>20 kHz ranges)

Accuracy

±5 % ±2 counts + source residual FM

(300 kHz IF, <15 kHz rate)

Modulation Rate

100 Hz to 40 kHz

Carrier Range

100 MHz to 2010 MHz

Minimum Carrier Level

-60 dBm (ANT Input Port)

Deviation Range

0 Rad to 10 Rad (Peak)

Resolution

0.01 Rad (deviation

5 Rad)

0.1 Rad (deviation >5 Rad)

Carrier Range

100 MHz to 2010 MHz

Minimum Carrier Level

-60 dBm (ANT Input Port)

Modulation Range

1 % to 90 %

Resolution

1 %

Accuracy

±5 % of full scale ±1 count + source residual AM

(30 % to 90 %)

Carrier Range

100 MHz to 2010 MHz

Minimum Carrier Level

-60 dBm (ANT Input Port)

Distortion Range

0.1 % to 20 %

Resolution

0.1 %

Accuracy

±0.5 % distortion ±1 count (1 % to 10 %)

±2 % distortion ±1 count (>10 %)

Signal Frequency

700 Hz to 1.4 kHz

Signal Level

0.1 VRMS to 30 VRMS (SINAD/BER input)

Input Range

NT 400 Channels

Cellular 800 MHz Channels

PCS 1900 MHz Channels

Minimum Carrier Level

-60 dBm (ANT connector)

EVM Range

0 to 100 %

EVM Resolution

0.01 %

Meter Residual EVM

<2 % indication

Accuracy

± 3.0% indication, ± 1 LSD + meter residual EVM

Range

3 dB to 30 dB

Resolution

0.1 dB

Accuracy

±1 dB ±1 count (at 12 dB SINAD)

Signal Frequency

700 Hz to 1.4 kHz

Signal Level

0.1 VRMS to 30 VRMS (SINAD/BER input)

VOLTMETER (DC/AC)
Ranges

200 mV to 200 V (full scale, decade sequence,

150

, 600

Ω,

1 M

selectable

)

Maximum Input

1000 VDC

500 VAC

Resolution

3.5 digit (maximum resolution 0.1 mV on 200 mV

range)

Accuracy

±5% of full scale ± 1 count (AC, where ACV*kHz

< 140)

±1% of full scale ± 1 count (DC)

Frequency

DC, 50 Hz to 20 kHz

Input Impedance

1 M

(±5%)

150

(±5%)

600

(±5%)

OHMMETER
Ranges

200

to 20 M

(full scale, decade sequence)

Resolution

3.5 digit (maximum resolution 0.1 on 200 range)

Accuracy

±5% or 0.1 (±1 count)

CURRENT METER (DC/AC)
Ranges

20 mA to 2 A (full scale, decade sequence, 20 A

maximum when using external shunt)

Resolution

3.5 digit (maximum resolution 0.01 mA on 20 mA

range)

Accuracy

±5 % or 0.1 mA ±1 count

Vertical BW

1 MHz (-3 dB)

Input Ranges

1 mV / Div to 50 V / Div (1-2-5 sequence, 8

divisions)

Max Input Vertical

200 V Peak

Accuracy Vertical

±5% of full scale

±10% of full scale (1 mV and 2 mV ranges)

Resolution Vertical

Full Scale / 256

Coupling Vertical

AC, DC, GND

Horizontal Sweep Rate

1 µSec / Div to 100 msec / Div (1-2-5 sequence,

10 divisions)

Accuracy Horizontal

±1 % of Full Scale

Resolution Horizontal

Full Scale / 400

External Input Impedance Horizontal

1 M

(shunted by 27 pF nominal)

Internal Signal Routing

425 kHz IF

Demod Audio

Function Generator

SINAD/BER

RF Power

EXT MOD

Range

10 MHz to 2010 MHz

Frequency Span Range

1 kHz/Div to 100 MHz/Div plus Zero Scan

(10 divisions in a 1-2-5 sequence)

Accuracy

±5% of Span Width

Reference Accuracy

See Master Oscillator

Display

Log, 10 dB/Div and 2 dB/Div

Vertical Resolution

Full Scale/256

Displayed Range (Dynamic)

60 dB (0 dB Attenuation, Span <1 MHz/Div)

Bandwidth Switching Error

<2 dB (5 kHz/Div thru 1 MHz/Div)

<3 dB (<5 kHz/Div or >1 MHz/Div)

Spectrum Analyzer

Oscilloscope

Digital Multimeter

SINAD Meter

Error Vector Magnitude (EVM) Meter

Distortion Meter

AM Modulation Meter

PM Deviation Meter

FM Deviation Meter

Receiver

RF Power Meter

RF Frequency Error Meter

RF Counter

IFR-1900 CSA

W

ireless - Radio test Sets

IFR-1900 CSA

3

http://www.ifrinternational.com