Functional Specifications (Cont’d)

OPTICAL INTERFACES

Optical interfaces

10 GigE LAN and 10 GigE WAN

Available wavelengths

850, 1310 and 1550 nm

ELECTRICAL INTERFACES

Electrical interfaces

Ext. clock DS1/E1 and clock output

Ext. clock DS1/E1

Line coding

DS1: AMI and B8ZS
E1: AMI and HDB3

Termination mode

DS1/E1: Term

Framing

DS1: SF and ESF
E1: PCM30, PCM30CRC, PCM31 and PCM31CRC

Clocking

Internal, external (BITS) and recovered

Clock output

Clock out

Clock out divider: 16, 32 and 64

TESTING

RFC 2544

Throughput, back-to-back, frame loss and latency measurements according to RFC 2544. Frame size: RFC-defined sizes, user-configurable.

BERT

Unframed layer 1 up to layer 4 with or without VLAN Q-in-Q

Patterns (BERT)

PRBS 2E9-1, PRBS 2E11-1, PRBS 2E15-1, PRBS 2E20-1, PRBS 2E23-1, PRBS 2E31-1, and up to ten user patterns

Error insertion (BERT)

FCS, bit, 64B/66B Block

Error measurement

LAN/WAN: jabber/giant, runt, undersize, oversize, FCS, 64B/66B Block
WAN: B1, B2, B3, REI-L, REI-P
UDP, TCP and IP header checksum

Error measurement (BERT)

Bit error, bit mismatch 0, bit mismatch 1, performance monitoring (G.821 and G.826)

Alarm insertion

LOS, link down, local fault, remote fault, LSS (BERT)
WAN: SEF, LOF, AIS-L, RDI-L, AIS-P, RDI-P, LCD-P, LOP-P, ERDI-PSD, ERDI-PCD, ERDI-PPD, UNEQ-P

Alarm detection

LOS, link down, local fault, remote fault, frequency offset, LSS (BERT)
WAN: SEF, LOF, AIS-L, RDI-L, AIS-P, RDI-P, LCD-P, LOP-P, ERDI-PSD, ERDI-PCD, ERDI-PPD, PLM-P, UNEQ-P, Link (WIS)

Service disruption time measurement (BERT) Defect or No Traffic mode. Disruption time statistics include shortest, longest, last, average, total and count.
Multistream generation

Capability to transmit up to 10 streams. Configuration parameters are: packet size, transmission mode (Burst, Ramp or Continuous),
MAC source/destination address, VLAN ID, VLAN priority, IP source/destination address, ToS field, DSCP field and
UDP source/destination port.

VLAN stacking

Capability to generate streams with up to three layers of VLAN (including IEEE802.1ad QinQ tagged VLAN) and to filter received traffic by VLAN ID or
VLAN priority at any of the stacked VLAN layers.

Traffic analysis

Capability to analyze the incoming traffic and provide statistics according to a set of up to 10 configurable filters. Filters can be configured
for MAC source/destination address, VLAN ID, VLAN priority, IP source/destination address, ToS field, DSCP field, TCP source/destination port and UDP
source/destination port. VLAN filtering can be applied to any of the stacked VLAN layers.

Ethernet statistics

Multicast, broadcast, unicast, N-unicast, pause frame, frame size distribution, bandwidth, utilization, frame rate, frame loss,
out-of-sequence frames, in-sequence frames.

Jitter statistics

Generation: packet jitter simulation: VoIP G.711, VoIP G.723.1, G.729, user-defined
Analysis: delay variation statistics (ms): min., max., last, average, number of samples, jitter measurement estimate

Flow control injection

Packet pause time

(frame analyzer)
Flow control statistics

Pause time, last pause time, max. pause time, min. pause time, paused frames, abort frames, frames Tx, frames Rx

(frame analyzer and RFC 2544)

ADDITIONAL TEST AND MESUREMENT FUNCTIONS

Power measurement

Supports optical power measurement, displayed in dBm.

Frequency generation and measurement

Supports clock frequency generation and measurements (i.e., received frequency and deviation of the input signal clock from nominal frequency).
Frequency offset generation:

Range: ±120 ppm
Resolution: ±1 ppm
Accuracy: ±4.6 ppm

Frequency offset measurement:

Range: ±150 ppm
Resolution: ±1 ppm
Accuracy: ±4.6 ppm

Signal label control and monitoring

Ability to configure and monitor J0 Trace, J1 Trace and payload signal label C2 (WAN).

Dual test set

Performs end-to-end, bidirectional performance testing (as required by leading standards bodies)—remote Packet Blazer
controlled via the LAN connection under test.

DHCP client

Capability to connect to a DHCP server to obtain its IP address and subnet mask to connect to the network.

Smart Loopback

Capability to return traffic to the local unit by swapping packet overhead up to layer 4 of the OSI stack.

ADDITIONAL FEATURES

Expert mode

Ability to set thresholds in RFC 2544 and BERT mode to provide a PASS/FAIL status.

Scripting

The built-in Visual Basic .NET scripting engine and embedded macrorecorder provide a simple means of automating test cases and routines.
Embedded scripting routines provide a powerful means of creating advanced test scripts.

a

Event logger

Supports logging of test results, and the ability to print, export (to a file), or export the information contained in the logging tool.

Power up and restore

a

In the event of a power failure to the unit, the active test configuration and results are saved and restored upon bootup.

Save and load configuration

Ability to store and load test configurations to/from non-volatile memory.

Configurable test views

Allows users to customize their test views, i.e., to dynamically insert or remove test tabs/windows, in addition to creating new
test windows, so as to accurately match their testing needs.

a

Configurable test timer

Allows a user to set a specific start and stop time for tests.

Test favorites

Capability to select and load from predefined or user-modified test conditions.

Report generation

Ability to generate test reports in the following user-selectable formats: .pdf, .html, .txt and .csv.

Graph

Allows to graphically display the test statistics of the performance (RFC 2544) and frame analysis tests.

Screen capturing

b

Capability to gather a snap-shot of the screen for future use.

Logger printing

b

Capability to send logger messages to a supported local printer.

Remote control

Remote control through Visual Guardian Lite software or VNC.