Atec Megger-HT1000-2 User Manual
Page 2
HT1000/2
Copper Wire Analyzer
n
Send and receive frequency spectrum through VDSL band.
n
Spectrum analyzer assists the technician in finding
interrupters that cause disruptions to DSL service - will read
to VDSL band
n
ADSL2+ and VDSL2 - with optional card installed, xDSL
cards allow technicians to interface with the CO (DSLAM)
and measure communication protocols, such as speed -
upstream and downstream, signal to noise ratios and
percent utilization.
n
HT1000/2 RFL uses three or four wire setup and
pinpoints fault size and location with simple
temperature and cable gage adjustments.
SPECIFICATIONS
(Model HT1000/2-A unless otherwise noted)
Feature Range/Accuracy:
(whichever is greater)
ACV
0 V to 250 V (±2%, ± 1 V)
DCV
0 V to ±300 V (±2%, ±1 V)
Resistance 0
Ω to 1,000 KΩ (±2%, ±1 Ω)
Leakage
1 MΩ to 999 MΩ (±3%), 150 V open
circuit output
Longitudinal balance
+30 dBrn to +80 dBrn (±2 dBrn)
Super Stress™
-10 dBrn to +30 dBrn (±2 dBrn)
Load coil detection
0 coil to 4 coils (±1 coil)
Loop current
0 mA to ±100 mA (±2%, ±1 mA)
Power influence
+40 dBrnC to +100 dBrnC (±2 dBrnC)
Noise (Voice Band)
0 dBrnC to +60 dBrnC (±2 dBrnC)
Loss (Voice Band)
-40 dBm to +10 dBm (±1 dBm)
Open meter
0 m (0 ft) to 900 m (3,000 ft)
±2%, ±1.5 m (5ft)
900 m (3,000 ft) to 15 km (50,000 ft)
(±3%)
Auto test
7 user-selectable auto test scripts,
200 pair storage, retest capability,
Incremental pair testing program
ID tone
Frequency: 577.5 Hz (±1%)
Amplitude: 0 dBm, 600 Ω (±1 dBm)
Caller ID
Yes
Wideband tone send
Frequency: 20 KHz to 9 MHz (±1%)
Amplitude: 0 dBm, 135 Ω (±1 dBm)
Wideband tone receive
Frequency: 20 KHz to 33 MHz
Amplitude: -90 dBm, +2 dBm
(±2 dBm)
Wideband loss
Frequency: 20 KHz to 33 MHz
Amplitude: -90 dBm, +2 dBm
(±2 dBm) RFL
Distance to fault: 0 – 3.000 m
(10,000 ft) ±0.5%, ±1 m (3 ft)
Maximum measurable fault resistance:
100 MΩ
Maximum locatable fault resistance:
2 MΩ
TDR
Dual trace, 12 trace memory storage,
Automatic pulse width selection, Pair
comparison mode, Split/crosstalk
mode, Intermittent fault location,
Closest range 0 – 8 m (25 ft),
Longest range 0 – 16.000 m (49,000 ft)
(@VOP = 0.7), Zoom mode
Wideband spectrum analyzer Frequency: 20 KHz to 33 MHz
Amplitude: -90 dBm to +10 dBm
(±2 dBm)
-130 dBm/Hz to -30 dBm/Hz
(±2 dBm/Hz)
Impulse noise
Amplitude: -45 dBm to +10 dBm
(±2 dBm)
Filters: F, G, J, None (30 MHz)
Voiceband spectrum analyzer Frequency: 50 Hz to 4,100 Hz
Amplitude: -64 dBm to 0 dBm
(±2 dBm)
-76 dBm/Hz to -12 dBm/Hz
(±2 dBm/Hz)
Display
High resolution, ¼ VGA graphics with
LED backlight
Batteries
Rechargeable nickel-metal hydride
Battery Life
Approximately 30 hours typical usage
Weight
0.8 kg (28 oz)
Dimensions
254 mm x 114.3 mm x 63.5 mm (10 in. x 4.5 in. x 2.5 in.)
Environmental
Weather and drop resistant in accordance with MIL-STD-810F
HT1000/2-C (VDSL2) Specifications
In addition to features of HT1000/2-A
Feature
Description
Standards compliance
VDSL2 G.993.2
Bandplans: 8, 12, 17, 30 MHz
Profiles: 8a, 8b, 8c, 8d, 12a, 12b,
17a, 30a
Plan 997, Plan 998
Link statistics
Connection Type (ADSL-VDSL2, RT)
HT1000/2-C-H
HPNA Specifications
In addition to features of HT1000/2-C
Feature
Description
Standards compliance
ITU G.9954 (Home PNA 3.1)
Parameters measured
Phy - Physical connection rate
PER - Packet error rate
SNR - Signal to noise ratio
Attn - Attenuation