beautypg.com

Atec Megger-HT1000-2 User Manual

Page 2

background image

HT1000/2

Copper Wire Analyzer

n

Send and receive frequency spectrum through VDSL band.

n

Spectrum analyzer assists the technician in finding

interrupters that cause disruptions to DSL service - will read
to VDSL band

n

ADSL2+ and VDSL2 - with optional card installed, xDSL

cards allow technicians to interface with the CO (DSLAM)
and measure communication protocols, such as speed -
upstream and downstream, signal to noise ratios and
percent utilization.

n

HT1000/2 RFL uses three or four wire setup and

pinpoints fault size and location with simple

temperature and cable gage adjustments.

SPECIFICATIONS

(Model HT1000/2-A unless otherwise noted)

Feature Range/Accuracy:

(whichever is greater)

ACV

0 V to 250 V (±2%, ± 1 V)

DCV

0 V to ±300 V (±2%, ±1 V)

Resistance 0

Ω to 1,000 KΩ (±2%, ±1 Ω)

Leakage

1 MΩ to 999 MΩ (±3%), 150 V open

circuit output

Longitudinal balance

+30 dBrn to +80 dBrn (±2 dBrn)

Super Stress™

-10 dBrn to +30 dBrn (±2 dBrn)

Load coil detection

0 coil to 4 coils (±1 coil)

Loop current

0 mA to ±100 mA (±2%, ±1 mA)

Power influence

+40 dBrnC to +100 dBrnC (±2 dBrnC)

Noise (Voice Band)

0 dBrnC to +60 dBrnC (±2 dBrnC)

Loss (Voice Band)

-40 dBm to +10 dBm (±1 dBm)

Open meter

0 m (0 ft) to 900 m (3,000 ft)

±2%, ±1.5 m (5ft)

900 m (3,000 ft) to 15 km (50,000 ft)

(±3%)
Auto test

7 user-selectable auto test scripts,

200 pair storage, retest capability,

Incremental pair testing program

ID tone

Frequency: 577.5 Hz (±1%)

Amplitude: 0 dBm, 600 Ω (±1 dBm)

Caller ID

Yes

Wideband tone send

Frequency: 20 KHz to 9 MHz (±1%)

Amplitude: 0 dBm, 135 Ω (±1 dBm)

Wideband tone receive

Frequency: 20 KHz to 33 MHz

Amplitude: -90 dBm, +2 dBm

(±2 dBm)

Wideband loss

Frequency: 20 KHz to 33 MHz

Amplitude: -90 dBm, +2 dBm

(±2 dBm) RFL

Distance to fault: 0 – 3.000 m

(10,000 ft) ±0.5%, ±1 m (3 ft)

Maximum measurable fault resistance:

100 MΩ

Maximum locatable fault resistance:

2 MΩ

TDR

Dual trace, 12 trace memory storage,

Automatic pulse width selection, Pair

comparison mode, Split/crosstalk

mode, Intermittent fault location,

Closest range 0 – 8 m (25 ft),

Longest range 0 – 16.000 m (49,000 ft)

(@VOP = 0.7), Zoom mode

Wideband spectrum analyzer Frequency: 20 KHz to 33 MHz

Amplitude: -90 dBm to +10 dBm

(±2 dBm)

-130 dBm/Hz to -30 dBm/Hz

(±2 dBm/Hz)

Impulse noise

Amplitude: -45 dBm to +10 dBm

(±2 dBm)

Filters: F, G, J, None (30 MHz)

Voiceband spectrum analyzer Frequency: 50 Hz to 4,100 Hz

Amplitude: -64 dBm to 0 dBm

(±2 dBm)

-76 dBm/Hz to -12 dBm/Hz

(±2 dBm/Hz)

Display

High resolution, ¼ VGA graphics with

LED backlight


Batteries
Rechargeable nickel-metal hydride
Battery Life

Approximately 30 hours typical usage

Weight
0.8 kg (28 oz)

Dimensions
254 mm x 114.3 mm x 63.5 mm (10 in. x 4.5 in. x 2.5 in.)

Environmental
Weather and drop resistant in accordance with MIL-STD-810F

HT1000/2-C (VDSL2) Specifications

In addition to features of HT1000/2-A

Feature

Description

Standards compliance

VDSL2 G.993.2

Bandplans: 8, 12, 17, 30 MHz

Profiles: 8a, 8b, 8c, 8d, 12a, 12b,

17a, 30a

Plan 997, Plan 998

Link statistics

Connection Type (ADSL-VDSL2, RT)

HT1000/2-C-H

HPNA Specifications
In addition to features of HT1000/2-C

Feature

Description

Standards compliance

ITU G.9954 (Home PNA 3.1)

Parameters measured

Phy - Physical connection rate

PER - Packet error rate

SNR - Signal to noise ratio

Attn - Attenuation