beautypg.com

Atec Acterna-JDSU-SDA-5000 User Manual

Page 7

background image

Automated tests can be scheduled to

perform either 24-hour FCC compliance

tests, or initiated immediately to log

performance at individual nodes,

amplifiers, or other testpoints. A wide

range of tests can be performed auto-

matically, including signal levels,

C/N, hum, and depth of modulation.

The operator designates which tests to

perform on which channels. Because

these tests are non-intrusive, it is easy

to test all parameters on all channels

at any time.

After a test is performed, the results

can be displayed on the SDA screen.

A PASS/FAIL indication on a variety

of limits can be set for FCC/CENELEC

or other government standards,

or system preferences. Data taken

during any automated test, or

sequence of automated tests, can be

viewed immediately with a PASS/FAIL

indication for each of the limits.

Specific stored measurement results

may be viewed on demand.

Data analysis with StealthWare

Test results can be printed directly to a

serial printer or uploaded to a PC using

Acterna StealthWare, a Microsoft

®

Windows

®

-based data management

package, to store and include in cus-

tom reports. Stored sweep, scan, or

spectrum screens can be viewed on

the PC and analyzed with marker move-

ment and readout information in just

the same way as on the actual instru-

ment. A sweep graph overlay function

allows comparison of multiple RF

response variations over time. Old

sweep graphs may be downloaded

back into the SDA instrument for real-

time comparison.

Powerful and intuitive standardized

graphical displays

All measurement results are presented

to the user in clear, highly informative,

summary displays. The graphics

present the information the way the

technician wants to see the results,

with no further interpretation required.

For example, testpoint compensation

values are entered at the start of

testing. Displays then calculate actual

levels automatically, minimizing

field errors.

Reduced training time

With SDA Series products, all levels of

instruments are familiar to the tech-

nician, regardless of which is learned

first, because the same user interface

conventions are used across all prod-

uct families. The time needed for a

trainee technician to learn to use the

instrument is considerably shorter

than with alternative test equipment.

This means urgent upgrade projects

make the most efficient use of limited

resources when SDA Series products

are used.

7

Limit checks can be instantly viewed after

identifying channel of interest with a marker

in Scan mode display

In-service carrier-to-noise

Tilt mode performs automatic tilt calculations

between any two of nine designated carriers