Telemetry

Frequency range

5 to 1000 MHz

Modulation

FSK, 100 kHz deviation

Spectrum required

1.0 MHz vacant bandwidth

recommended

Spectral purity

Hars 30 dBc; Spurs 35 dBc

Data storage

Files stored: auto tests, tilt, channel plans, scan
and forward sweep. Also reverse sweep and reverse
amp alignment on SDA-5000 with option 1 and/or 2.
Spectrum mode (regular with max hold and
CSO/CTB). Allocated on demand. The storage capa-
bility is simultaneous – more of one file type can
be “traded” for less of another. All files stored as
database, not as screen picture. (Example: typical
mix of files for 78-channel plan: 8 channel plans,
16 sweep references, 80 sweep traces, 40 scan
files, 20 spectrum displays and 20 auto tests).

Serial interface

RS232; Epson, IBM, Seiko, and Diconix Printers

Input configuration

Connector type

75

Ω type F female

(optional 75

Ω type BNC female)

Maximum sustained voltage

AC 100V DC 140V

General

Display

320 x 240 dot matrix LCD,

selectable backlight

(SDA-5000 only)

Dimensions

6 x 11 x 3.5 in

(15.2 x 27.9 x 8.9 cm)

Weight

5.1 lb (2.3 kg)

(with option 1 or 2, 5.5 lb (2.5 kg))

Temperature range operating

20 to +47°C

(4 to 117°F)

(SDA-5500 and SDA-5510 only)

Dimensions

19 x 5.25 x 14 in

(48.3 x 13.3 x 35.6 cm)

Weight

15 lb (6.8 kg)

Temperature range operating

0 to +50°C

(32 to 120°F)

Power sources

Battery

field extended-life replaceable,

nickel metal hydride

12V/3.5A-hr, 4 hours continuous

use on a single charge

AC line (SDA-5000)

Charger input

100 to 250 VAC,

50 to 60 Hz, 0.5 A

Charger output

aux out 16 V at 750 mA

Charge 15 V at 750 mA

AC line (SDA-5500)

100 to 265 to 63 Hz ~100 VAC

47 to 63 Hz ~100 VA

Sweep mode

(SDA-5000 and 5500 only)
Frequency range

5 to 1000 MHz

Display span

User definable

Display scale/range

6 vertical divisions 1, 2, 5,

or 10 dB/division

Sweep pulse occupied bandwidth

30 kHz

Stability

±0.5 dB, normalized

(dependent on stability of referenced carriers)

Sweep rate

~1 second (78 channels, including

scrambled and digital signal types)

Channel plan templates (user editable)

China-1; China-2; France; HDTP-NL; Ireland;

Japan; Jerold; Jerold-HRC; Jerold-IRC;

NCTA; NCTA-HRC; NCTA-SUB; NCTA-IRC;

NTSC-Broadcast; OIRT-D/K; PL-B/G; PAL-UK

Spectrum mode

Spans

3, 5, 10, 20, and 50 MHz

(0.3, 0.5, 1, 2, and 5 MHz/div)

Sweep rates

~1 second updates

with spans of 50, 20,

10 and 5 MHz ~1.7 second

updates with 3 MHz span

Display scaling and range

0.5, 1, 2, 5,

and 10 dB/div

6 vertical divisions

Dwell

programmable 0-25 ms

Spurious free dynamic range

60 dB3

Sensitivity without preamp 40 dBmV 5 to 550 MHz

35 dBmV 550 to 1000 MHz

Sensitivity with preamp

50 dBmV 5 to 550 MHz

45 dBmV 550 to 1000 MHz

Maximum level with preamp

+50 dBmV

Zero Span mode

Video BW

> 1 MHz, 100 kHz, 10 kHz, 100 Hz

Resolution BW

2 MHz, 280 kHz, 30 kHz

Measurement BW

1 kHz to 99 MHz

compensation programmable

Pulse measurement accuracy

nominal level in 10 µs

±2 dB from nominal in 5 µs

(> 1 MHz VBW, 280 kHz RBW)

Sweep times

100 µs to 20 s (1, 2, 5 settings)

Intermodulation distortion (CSO/CTB)

Range

(5)

≥ 60 dB

Resolution

0.1 dB

Forward transmitter

(SDA-5000 with option 2/SDA-5500 only)
Frequency range

5 to 1000 MHz

Output level

+20 to +50 dBmV adjustable

in 2 dB increments

Spectral purity

Hars 30 dBc

Spurs 35 dBc

Reverse transmitter

(Requires SDA-5000 with option 1 or 2)
Frequency range

5 to 1000 MHz

Output level

+20 to +50 dBmV,

adjustable in 2 dB increments

Spectral purity

Hars 30 dBc; Spurs 35 dBc

60

50

40

30

20

10

0

–10

0

10

14

Carrier to Noise Range (dB)

Video Carrier Level (dBmV)

60

50

40

30

20

10

0

–20

–10

0

10

24

20

30

Depth of Measurement (dB)

(without preamplification/with preselection

Video Carrier Level (dBmV)

±2.0 dB Accuracy

±3 dB Accuracy

Out of measurement range

Out of measurement range

±3 dB Accuracy

±2.0 dB Accuracy

PathTrak Field View (opt 3 required)

(SDA-5000 and SDA-5500 only)
Update rate

2x/second (remote trace)

~1x/second (local trace)

Display scaling

5/1/2/5/10/20 dB/div.

Selectable nodes

14 (selectable via

PathTrak HCU)

QAM View option (opt 4)

The QAM View option can be factory installed in
any new or existing SDA Series instrument. The
specifications and features are in addition to the
standard measurement features of the SDA Series.
When ordering, please specify option 4a for 8 MHz,
DVB-C, ITU-T J.83 annex A, or option 4b for 6 MHz,
DVS-031, ITU-T J.83 annex B.

Modulation type

64/256 QAM, DVB-C,

ITU-T J.83 annex A (option 4a)

64/256 QAM, DVS-031,

ITU-T J.83 annex B (option 4b)

Channel bandwidth

8 MHz (option 4A);

6 MHz (option 4B)

Notes

(1)

Typical specifications

(2)

Relative to 25°C

(3)

At 25°C and +20 dBmV

(4)

(5)