Spectrum Master™ MS2721B Spectrum Analyzer Specifications
General Specifications
All specifications and characteristics apply under the following conditions, unless otherwise stated: 1) After 5 minutes of warm-up time, where the
instrument is left in the ON state; 2) All specifications apply when using internal reference; 3) All specifications subject to change without notice;
4) Typical performance is the measured performance of an average unit; 5) Recommended calibration cycle is 12 months.
Maximum Continuous Input
(≥ 10 dB input attenuation) +30 dBm
Input Damage Level
≥ 10 dB input attenuation, > +43 dBm, ± 50 Vdc. Input protection relay opens at > 30 dBm
< 10 dB input attenuation, > +23 dBm, ± 50 Vdc. Limited dV/dt. Input protection relay
opens at approximately 10 to 23 dBm
ESD Damage Level
(≥ 10 dB input attenuation) > 10 kV
External Reference Frequencies
1 MHz, 1.2288 MHz, 1.544 MHz, 2.048 MHz, 2.4576 MHz, 4.8 MHz, 4.9152 MHz, 5 MHz,
9.8304 MHz, 10 MHz, 13 MHz and 19.6608 MHz at –10 dBm to +10 dBm
Setup Parameters
System
Status (Temperature, Battery Info, S/N, Firmware Ver, IP Address, Options Installed)
Self Test, Application Self Test
GPS (see Option 0031)
System Options
Name, Date and Time, Ethernet Configuration, Brightness, Volume
Language (English, French, German, Spanish, Chinese, Japanese, Korean, Italian, User defined)
Reset (Factory Defaults, Master Reset, Update Firmware)
File
Save, Recall, Delete, Directory Management
Save/Recall
Setups, Measurements, Screen Shots Jpeg (save only)
Delete
Selected File, All Measurements, All Mode Files, All Content
Directory Management
Sort Method (Name/Type/Date), Ascend/Descend, Internal/USB, Copy, Format USB
Internal Trace/Setup Memory
> 13,000 traces
External Trace/Setup Memory
Limited by size of USB Flash drive or Compact Flash module
Mode Switching
Auto-Stores/Recalls most recently used Setup Parameters in the Mode
Connectors
RF In
Type N, female, 50 Ω, Maximum Input +30 dBm, ± 50 VDC
GPS
BNC, female, reverse polarity
External Power
5.5 mm barrel connector, 12 to 15 VDC, < 5.0 Amps
LAN Connection
RJ48C, 10/100 Mbps, Connect to PC or LAN for Remote Access
Compact Flash Interface
Type I
USB Interface
Type A, Connect Flash Drive and Power Sensor
USB Interface
5-pin mini-B, Connect to PC for data transfer
Headset
2.5 mm minature phone plug
External Trigger In
BNC, female, 50 Ω, Maximum Input ± 5 VDC
Display
Size
8.4”
Resolution
800 x 600
Battery
Type
Li-Ion
Battery Operation
2.5 hours, typical
Electromagnetic Compatibility
European Union
CE Mark, EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC and
Low Voltage Directive 73/23/EEC, 93/68/EEC
Australia and New Zealand
C-tick N274
Interference
EN 61326-1
Emissions
EN 55011
Immunity
EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-11
Safety
Safety Class
EN 61010-1 Class 1
Product Safety
IEC 60950-1 when used with Company supplied Power Supply
Environmental
Operating Temperature
–10 ºC to 55 ºC
Maximum Humidity
85%
Shock
MIL-PRF-28800F Class 2
Storage
–51 ºC to 71 ºC
Altitude
4600 meters, operating and non-operating
Size and Weight
Size
315 mm x 211 mm x 94 mm, (12.4 in x 8.3 in x 3.7 in)
Weight
3.1 kg, (6.9 lbs)