Specifications for analog modulation – Atec Agilent-E4438C User Manual
Page 12
12
Band Frequency
range
N
number
1
250 kHz to
≤ 250 MHz
1
2
> 250 MHz to
≤ 500 MHz
0.5
3
> 500 MHz to
≤ 1GHz
1
4
> 1 to
≤ 2 GHz
2
5
> 2 to
≤ 4 GHz
4
6
> 4 to
≤ 6 GHz
8
Maximum deviation
3
Standard
With Option UNJ
N x 8 MHz
N x 1 MHz
Resolution
0.1% of deviation or 1 Hz,
whichever is greater
Modulation frequency rate
4
[deviation = 100 kHz]
Coupling
1 dB bandwidth
3 dB bandwidth
FM path 1[DC]
DC to 100 kHz
(DC to 10 MHz)
FM path 2 [DC]
DC to 100 kHz
(DC to 0.9 MHz)
FM path 1 [AC]
20 Hz to 100 kHz
(5 Hz to 10 MHz)
FM path 2 [AC]
20 Hz to 100 kHz
(5 Hz to 0.9 MHz)
Deviation accuracy
3
[1 kHz rate, deviation < N x 100 kHz]
< ± 3.5% of FM deviation + 20 Hz
Carrier frequency accuracy relative to CW in DCFM
3, 5
±0.1% of set deviation + (N x 1 Hz)
Distortion
3
[1 kHz rate, dev.= N x 100 kHz]
< 1%
FM using external inputs 1 or 2
Sensitivity
1 V
peak
for indicated deviation
Input impedance
50
Ω, nominal
FM path 1 and FM path 2 are summed internally for composite modulation.
The FM 2 path is limited to a maximum rate of 1 MHz. The FM 2 path must be
set to a deviation less than FM 1 path.
Specifications for Analog Modulation
1. All analog performance above 4 GHz is typical.
2. For non-Option UNJ units, specifications apply in phase noise mode 2 [default].
3. Refer to frequency bands on this page to compute specifications.
4. Parentheses denote typical performance.
5. At the calibrated deviation and carrier frequency, within 5 °C of ambient temperature at time of calibration.
Frequency bands
Frequency modulation
1 ,2