beautypg.com

Specifications for analog modulation – Atec Agilent-E4438C User Manual

Page 12

background image

12

Band Frequency

range

N

number

1

250 kHz to

≤ 250 MHz

1

2

> 250 MHz to

≤ 500 MHz

0.5

3

> 500 MHz to

≤ 1GHz

1

4

> 1 to

≤ 2 GHz

2

5

> 2 to

≤ 4 GHz

4

6

> 4 to

≤ 6 GHz

8

Maximum deviation

3

Standard

With Option UNJ

N x 8 MHz

N x 1 MHz

Resolution

0.1% of deviation or 1 Hz,
whichever is greater

Modulation frequency rate

4

[deviation = 100 kHz]

Coupling

1 dB bandwidth

3 dB bandwidth

FM path 1[DC]

DC to 100 kHz

(DC to 10 MHz)

FM path 2 [DC]

DC to 100 kHz

(DC to 0.9 MHz)

FM path 1 [AC]

20 Hz to 100 kHz

(5 Hz to 10 MHz)

FM path 2 [AC]

20 Hz to 100 kHz

(5 Hz to 0.9 MHz)

Deviation accuracy

3

[1 kHz rate, deviation < N x 100 kHz]

< ± 3.5% of FM deviation + 20 Hz

Carrier frequency accuracy relative to CW in DCFM

3, 5

±0.1% of set deviation + (N x 1 Hz)

Distortion

3

[1 kHz rate, dev.= N x 100 kHz]

< 1%

FM using external inputs 1 or 2

Sensitivity

1 V

peak

for indicated deviation

Input impedance

50

Ω, nominal

FM path 1 and FM path 2 are summed internally for composite modulation.
The FM 2 path is limited to a maximum rate of 1 MHz. The FM 2 path must be
set to a deviation less than FM 1 path.

Specifications for Analog Modulation

1. All analog performance above 4 GHz is typical.
2. For non-Option UNJ units, specifications apply in phase noise mode 2 [default].
3. Refer to frequency bands on this page to compute specifications.
4. Parentheses denote typical performance.
5. At the calibrated deviation and carrier frequency, within 5 °C of ambient temperature at time of calibration.

Frequency bands

Frequency modulation

1 ,2