beautypg.com

Atec Agilent-33521A-33522A User Manual

Page 7

background image

7

Burst

9

Type

Counted or gated

Count

1 to 1x10

8

cycles, or infinite

Gated

Produces complete cycles while Ext Trig is asserted

Start/stop phase

4

-360° to 360°, 0.1° resolution

Trigger source

Internal Timer or Ext Trig connector

Marker

Adjustable to any cycle; indicated by the trailing edge of the Sync pulse

Sweep

7

Type

Linear, Logarithmic, List (up to 128 user-defined frequencies)

Operation

Linear and Logarithmic sweeps are characterized by a Sweep time (during which
the frequency changes smoothly from Start to Stop), a Hold time (during which
the frequency stays at the Stop frequency), and a Return time (during which the
frequency changes smoothly from Stop to Start). Returns are always linear.

Direction

Up (Start freq < Stop freq) or Down (Start freq > Stop freq)

Start and stop frequencies

Any frequency within the waveform's range

Sweep time

Linear:

1 ms to 3600 s, 1 ms resolution;

3601 s to 250,000 s, 1 s resolution

Logarithmic: 1 ms to 500 s

Hold time

0 s to 3600 s, 1 ms resolution

Return time

0 s to 3600 s, 1 ms resolution

Trigger source

10

Immediate (continuous), external, single, bus, or timer

Marker

Adjustable to any frequency between Start and Stop for Linear
and Logarithmic types or any frequency in the list for List type;
indicated by the trailing edge of the sync pulse

Internal timer for FSK, BPSK, BURST, and SWEEP

Range

1 µs to 8000s, 6-digit or 4 ns resolution

2-channel characteristics (33522A only)

Operating modes

Independent, coupled parameter(s), combined (Ch 1 + Ch 2),
Equal (Ch 2 = Ch 1), or differential (Ch 2 = -Ch 1)

Parameter coupling

None, frequency (ratio or difference) and/or amplitude and DC offset

Relative phase

0° to 360°, 0.1° resolution

Skew (typ)

< 200 ps (when performing identical operations)

Crosstalk (typ)

< -85 dB